{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-54005 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-54005 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-54005 is a medium-severity vulnerability in Siemens COMOS V10.3, published on 10 Dec 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-54005 and fix it if it is affected.\n\nWhat it is: CVE-2024-54005 is a medium-severity vulnerability in Siemens COMOS V10.3, published on 10 Dec 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-54005 in the wild and no public exploit code.\n\nAffected product: Siemens COMOS V10.3. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-54005/ (Markdown: https://insights.sbomify.com/CVE-2024-54005/index.md)","id":"CVE-2024-54005","markdown":"https://insights.sbomify.com/CVE-2024-54005/index.md","name":"CVE-2024-54005","record":{"aliases":["GHSA-w23f-22px-mx2g"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens COMOS","requires_auth":"none","summary":"An attacker can extract files from the user's system or network by injecting malicious XML data into the PDMS/E3D Engineering Interface communication channel.","user_interaction":"not_required","vuln_class":"xxe"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":5.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-611","name":"Improper Restriction of XML External Entity Reference"}],"description":"A vulnerability has been identified in COMOS V10.3 (All versions \u003c V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions \u003c V10.4.3.0.47), COMOS V10.4.4 (All versions \u003c V10.4.4.2), COMOS V10.4.4.1 (All versions \u003c V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"XML external entity in COMOS V10.3","id":"CVE-2024-54005","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xxe","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Authenticated Remote Command Injection Vulnerability in the Web Interface of a 501 Wireless Client Bridge","id":"CVE-2024-54006"},"packages":[],"prev":{"headline":"Jenkins Filesystem List Parameter Plugin has Path Traversal vulnerability","id":"CVE-2024-54004"},"products":["COMOS V10.3","COMOS V10.4.0","COMOS V10.4.1","COMOS V10.4.2","COMOS V10.4.3","COMOS V10.4.4","COMOS V10.4.4.1"],"published":"2024-12-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-12-10","vendors":["Siemens"]},"summary":"An attacker can extract files from the user's system or network by injecting malicious XML data into the PDMS/E3D Engineering Interface communication channel.","url":"https://insights.sbomify.com/CVE-2024-54005/"}