{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-54017 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-54017 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-54017 is a medium-severity vulnerability in Siemens SIPROTEC 5 6MD84 (CP300), published on 12 May 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-54017 and fix it if it is affected.\n\nWhat it is: CVE-2024-54017 is a medium-severity vulnerability in Siemens SIPROTEC 5 6MD84 (CP300), published on 12 May 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-54017 in the wild and no public exploit code.\n\nAffected product: Siemens SIPROTEC 5 6MD84 (CP300). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-54017/ (Markdown: https://insights.sbomify.com/CVE-2024-54017/index.md)","id":"CVE-2024-54017","markdown":"https://insights.sbomify.com/CVE-2024-54017/index.md","name":"CVE-2024-54017","record":{"aliases":["GHSA-wv47-qqcp-w8j2"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SIPROTEC 5","requires_auth":"none","summary":"Weak random number generation in Siemens SIPROTEC 5 devices allows attackers to bypass security controls, requiring firmware upgrades to mitigate.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-334","name":"Small Space of Random Values"}],"description":"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V11.0), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SA82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SA84 (CP200) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SD82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SD84 (CP200) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SK82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SL82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7SX85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7UT82 (CP100) (All versions \u003e= V7.80), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V11.0), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V7.80 \u003c V11.0), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003c V11.0). Affected devices do not use  sufficiently random values to create session identifiers. This could allow an unauthenticated remote attacker to brute force a session identifier and gain read access to limited  information from the web server without authorization.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Weak cryptography in SIPROTEC 5 6MD84 (CP300)","id":"CVE-2024-54017","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in FortiSandbox","id":"CVE-2024-54018"},"packages":[],"prev":{"headline":"compression bomb attack in Apache Seata Server","id":"CVE-2024-54016"},"products":["SIPROTEC 5 6MD84 (CP300)","SIPROTEC 5 6MD85 (CP200)","SIPROTEC 5 6MD85 (CP300)","SIPROTEC 5 6MD86 (CP200)","SIPROTEC 5 6MD86 (CP300)","SIPROTEC 5 6MD89 (CP300)","SIPROTEC 5 6MU85 (CP300)","SIPROTEC 5 7KE85 (CP200)","SIPROTEC 5 7KE85 (CP300)","SIPROTEC 5 7SA82 (CP100)","SIPROTEC 5 7SA82 (CP150)","SIPROTEC 5 7SA84 (CP200)","SIPROTEC 5 7SA86 (CP200)","SIPROTEC 5 7SA86 (CP300)","SIPROTEC 5 7SA87 (CP200)","SIPROTEC 5 7SA87 (CP300)","SIPROTEC 5 7SD82 (CP100)","SIPROTEC 5 7SD82 (CP150)","SIPROTEC 5 7SD84 (CP200)","SIPROTEC 5 7SD86 (CP200)","SIPROTEC 5 7SD86 (CP300)","SIPROTEC 5 7SD87 (CP200)","SIPROTEC 5 7SD87 (CP300)","SIPROTEC 5 7SJ81 (CP100)","SIPROTEC 5 7SJ81 (CP150)","SIPROTEC 5 7SJ82 (CP100)","SIPROTEC 5 7SJ82 (CP150)","SIPROTEC 5 7SJ85 (CP200)","SIPROTEC 5 7SJ85 (CP300)","SIPROTEC 5 7SJ86 (CP200)","SIPROTEC 5 7SJ86 (CP300)","SIPROTEC 5 7SK82 (CP100)","SIPROTEC 5 7SK82 (CP150)","SIPROTEC 5 7SK85 (CP200)","SIPROTEC 5 7SK85 (CP300)","SIPROTEC 5 7SL82 (CP100)","SIPROTEC 5 7SL82 (CP150)","SIPROTEC 5 7SL86 (CP200)","SIPROTEC 5 7SL86 (CP300)","SIPROTEC 5 7SL87 (CP200)","SIPROTEC 5 7SL87 (CP300)","SIPROTEC 5 7SS85 (CP200)","SIPROTEC 5 7SS85 (CP300)","SIPROTEC 5 7ST85 (CP200)","SIPROTEC 5 7ST85 (CP300)","SIPROTEC 5 7ST86 (CP300)","SIPROTEC 5 7SX82 (CP150)","SIPROTEC 5 7SX85 (CP300)","SIPROTEC 5 7SY82 (CP150)","SIPROTEC 5 7UM85 (CP300)","SIPROTEC 5 7UT82 (CP100)","SIPROTEC 5 7UT82 (CP150)","SIPROTEC 5 7UT85 (CP200)","SIPROTEC 5 7UT85 (CP300)","SIPROTEC 5 7UT86 (CP200)","SIPROTEC 5 7UT86 (CP300)","SIPROTEC 5 7UT87 (CP200)","SIPROTEC 5 7UT87 (CP300)","SIPROTEC 5 7VE85 (CP300)","SIPROTEC 5 7VK87 (CP200)","SIPROTEC 5 7VK87 (CP300)","SIPROTEC 5 7VU85 (CP300)","SIPROTEC 5 Compact 7SX800 (CP050)"],"published":"2026-05-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-05-13","vendors":["Siemens"]},"summary":"Weak random number generation in Siemens SIPROTEC 5 devices allows attackers to bypass security controls, requiring firmware upgrades to mitigate.","url":"https://insights.sbomify.com/CVE-2024-54017/"}