{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-54090 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-54090 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-54090 is a medium-severity vulnerability in Siemens APOGEE PXC Series (BACnet), published on 11 Feb 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-54090 and fix it if it is affected.\n\nWhat it is: CVE-2024-54090 is a medium-severity vulnerability in Siemens APOGEE PXC Series (BACnet), published on 11 Feb 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-54090 in the wild and no public exploit code.\n\nAffected product: Siemens APOGEE PXC Series (BACnet). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-54090/ (Markdown: https://insights.sbomify.com/CVE-2024-54090/index.md)","id":"CVE-2024-54090","markdown":"https://insights.sbomify.com/CVE-2024-54090/index.md","name":"CVE-2024-54090","record":{"aliases":["GHSA-wh5p-642q-7g8m"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["denial_of_service","other"],"network_reachable":"yes","non_default_config":false,"product_category":"Building automation controller","requires_auth":"low_privilege","summary":"An attacker with medium privileges can trigger an out-of-bounds read in Siemens building automation controllers, causing a denial of service via insecure cold start.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":6,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-125","name":"Out-of-bounds Read"}],"description":"A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function.\r\nThis could allow an attacker with Medium (MED) or higher privileges to cause the device to enter an insecure cold start state.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in APOGEE PXC Series (BACnet)","id":"CVE-2024-54090","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in Solid Edge SE2024","id":"CVE-2024-54091"},"packages":[],"prev":{"headline":"Weak cryptography in APOGEE PXC Series (BACnet)","id":"CVE-2024-54089"},"products":["APOGEE PXC Series (BACnet)","APOGEE PXC Series (P2 Ethernet)","TALON TC Series (BACnet)"],"published":"2025-02-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-12","vendors":["Siemens"]},"summary":"An attacker with medium privileges can trigger an out-of-bounds read in Siemens building automation controllers, causing a denial of service via insecure cold start.","url":"https://insights.sbomify.com/CVE-2024-54090/"}