{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2024-5557 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-5557 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-5557 is a medium-severity vulnerability in Schneider Electric SpaceLogic AS-B, published on 12 Jun 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-5557 and fix it if it is affected.\n\nWhat it is: CVE-2024-5557 is a medium-severity vulnerability in Schneider Electric SpaceLogic AS-B, published on 12 Jun 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-5557 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SpaceLogic AS-B. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-5557/ (Markdown: https://insights.sbomify.com/CVE-2024-5557/index.md)","id":"CVE-2024-5557","markdown":"https://insights.sbomify.com/CVE-2024-5557/index.md","name":"CVE-2024-5557","record":{"aliases":["GHSA-r3pr-q6h2-2wph"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SpaceLogic controller","requires_auth":"high_privilege","summary":"Attackers with log access can expose SNMP credentials in SpaceLogic AS-B and AS-P controllers, requiring vendor patches.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"spacelogic_as-b_firmware","vendor":"schneider-electric"},{"product":"spacelogic_as-p_firmware","vendor":"schneider-electric"}],"cvss":{"score":4.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-532","name":"Insertion of Sensitive Information into Log File"}],"description":"CWE-532: Insertion of Sensitive Information into Log File vulnerability exists that could cause\nexposure of SNMP credentials when an attacker has access to the controller logs.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in SpaceLogic AS-B","id":"CVE-2024-5557","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Race condition in SpaceLogic AS-B","id":"CVE-2024-5558"},"packages":[],"prev":{"headline":"SQL Injection","id":"CVE-2024-5556"},"products":["SpaceLogic AS-B","SpaceLogic AS-P"],"published":"2024-06-12","related":[{"cvss_score":6.4,"headline":"Race condition in SpaceLogic AS-B","id":"CVE-2024-5558","kev_date_added":null,"published":"2024-06-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-01","vendors":["Schneider Electric"]},"summary":"Attackers with log access can expose SNMP credentials in SpaceLogic AS-B and AS-P controllers, requiring vendor patches.","url":"https://insights.sbomify.com/CVE-2024-5557/"}