{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-56182 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-56182 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-56182 is a high-severity vulnerability in Siemens SIMATIC Field PG M5, published on 11 Mar 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-56182 and fix it if it is affected.\n\nWhat it is: CVE-2024-56182 is a high-severity vulnerability in Siemens SIMATIC Field PG M5, published on 11 Mar 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-56182 in the wild and no public exploit code.\n\nAffected product: Siemens SIMATIC Field PG M5. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-56182/ (Markdown: https://insights.sbomify.com/CVE-2024-56182/index.md)","id":"CVE-2024-56182","markdown":"https://insights.sbomify.com/CVE-2024-56182/index.md","name":"CVE-2024-56182","record":{"aliases":["GHSA-x7x2-6gw9-jg8m"],"analysis":{"component_type":"hardware_firmware","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens SIMATIC IPC","requires_auth":"high_privilege","summary":"An authenticated attacker can bypass BIOS password protection by directly communicating with the flash controller due to insufficient EFI variable protection.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":8.4,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-693","name":"Protection Mechanism Failure"}],"description":"A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC Field PG M6 (All versions \u003c V26.01.12), SIMATIC IPC BX-21A (All versions \u003c V31.01.07), SIMATIC IPC BX-32A (All versions \u003c V29.01.07), SIMATIC IPC BX-39A (All versions \u003c V29.01.07), SIMATIC IPC BX-59A (All versions \u003c V32.01.04), SIMATIC IPC PX-32A (All versions \u003c V29.01.07), SIMATIC IPC PX-39A (All versions \u003c V29.01.07), SIMATIC IPC PX-39A PRO (All versions \u003c V29.01.07), SIMATIC IPC RC-543A (All versions \u003c V36.01.03), SIMATIC IPC RC-543B (All versions \u003c V35.01.12), SIMATIC IPC RW-543A (All versions \u003c V1.1.4), SIMATIC IPC RW-543B (All versions \u003c V35.02.10), SIMATIC IPC127E (All versions \u003c V27.01.11), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions \u003c V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions \u003c V28.01.14), SIMATIC IPC277G PRO (All versions \u003c V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions \u003c V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions \u003c V28.01.14), SIMATIC IPC427E (All versions \u003c V21.01.21), SIMATIC IPC477E (All versions \u003c V21.01.21), SIMATIC IPC477E PRO (All versions \u003c V21.01.21), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions \u003c V25.02.15), SIMATIC IPC647E (All versions \u003c V25.02.15), SIMATIC IPC677E (All versions \u003c V25.02.15), SIMATIC IPC847E (All versions \u003c V25.02.15), SIMATIC ITP1000 (All versions). The affected devices have insufficient protection mechanism for the EFI(Extensible Firmware Interface) variables stored on the device. This could allow an authenticated attacker to disable the BIOS password without proper authorization by directly communicate with the flash controller.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Security feature bypass in SIMATIC Field PG M5","id":"CVE-2024-56182","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in Android","id":"CVE-2024-56184"},"packages":[],"prev":{"headline":"Security feature bypass in SIMATIC Field PG M5","id":"CVE-2024-56181"},"products":["SIMATIC Field PG M5","SIMATIC Field PG M6","SIMATIC IPC BX-21A","SIMATIC IPC BX-32A","SIMATIC IPC BX-39A","SIMATIC IPC BX-59A","SIMATIC IPC PX-32A","SIMATIC IPC PX-39A","SIMATIC IPC PX-39A PRO","SIMATIC IPC RC-543A","SIMATIC IPC RC-543B","SIMATIC IPC RW-543A","SIMATIC IPC RW-543B","SIMATIC IPC127E","SIMATIC IPC227E","SIMATIC IPC227G","SIMATIC IPC277E","SIMATIC IPC277G","SIMATIC IPC3000 SMART V3","SIMATIC IPC327G","SIMATIC IPC347G","SIMATIC IPC377G","SIMATIC IPC427E","SIMATIC IPC477E","SIMATIC IPC477E PRO","SIMATIC IPC527G","SIMATIC IPC627E","SIMATIC IPC647E","SIMATIC IPC677E","SIMATIC IPC847E","SIMATIC ITP1000","SIMATIC IPC277G PRO"],"published":"2025-03-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-09-08","vendors":["Siemens"]},"summary":"An authenticated attacker can bypass BIOS password protection by directly communicating with the flash controller due to insufficient EFI variable protection.","url":"https://insights.sbomify.com/CVE-2024-56182/"}