{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-57575 exists.","fix":"No fix has been published for CVE-2024-57575 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-57575 is a critical memory corruption vulnerability in Tenda Ac18 Firmware, published on 16 Jan 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-57575 and fix it if it is affected.\n\nWhat it is: CVE-2024-57575 is a critical memory corruption vulnerability in Tenda Ac18 Firmware, published on 16 Jan 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-57575 exists.\n\nAffected product: Tenda Ac18 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-57575/ (Markdown: https://insights.sbomify.com/CVE-2024-57575/index.md)","id":"CVE-2024-57575","markdown":"https://insights.sbomify.com/CVE-2024-57575/index.md","name":"CVE-2024-57575","record":{"aliases":["GHSA-vcg8-v453-837w"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC18 router","requires_auth":"none","summary":"A stack overflow in the Tenda AC18 router allows attackers to execute arbitrary code or cause a denial of service via the ssid parameter.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"ac18_firmware","vendor":"tenda"}],"cvss":{"score":9.8,"severity":"critical","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"}],"description":"Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Memory corruption in n/a","id":"CVE-2024-57575","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac18_firmware","products":["tenda:ac18_firmware"],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Memory corruption in n/a","id":"CVE-2024-57577"},"packages":[],"prev":{"headline":"Cross Site Scripting vulnerability in store2","id":"CVE-2024-57556"},"products":["n/a"],"published":"2025-01-16","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57579","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57580","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57581","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57582","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-57583","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-33835","kev_date_added":null,"published":"2024-05-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-03","vendors":["n/a"]},"summary":"A stack overflow in the Tenda AC18 router allows attackers to execute arbitrary code or cause a denial of service via the ssid parameter.","url":"https://insights.sbomify.com/CVE-2024-57575/"}