{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-6242 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-6242 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-6242 is a high-severity vulnerability in Rockwell Automation 1756-EN2F, published on 1 Aug 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-6242 and fix it if it is affected.\n\nWhat it is: CVE-2024-6242 is a high-severity vulnerability in Rockwell Automation 1756-EN2F, published on 1 Aug 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-6242 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation 1756-EN2F. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-6242/ (Markdown: https://insights.sbomify.com/CVE-2024-6242/index.md)","id":"CVE-2024-6242","markdown":"https://insights.sbomify.com/CVE-2024-6242/index.md","name":"CVE-2024-6242","record":{"aliases":["GHSA-6h2q-3m5q-wv4c"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_modify","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Rockwell Logix controller","requires_auth":"low_privilege","summary":"Attackers can bypass Trusted Slot restrictions to execute CIP commands that modify user projects and device configurations on Logix controllers.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Rockwell","cpe":[],"cvss":{"score":7.3,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-420","name":"Unprotected Alternate Channel"}],"description":"A vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted® Slot feature in a ControlLogix® controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Rockwell Automation Chassis Restrictions Bypass Vulnerability in Select Logix Devices","id":"CVE-2024-6242","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"HTML Forms \u003c 1.3.33 - Admin+ Stored XSS","id":"CVE-2024-6243"},"packages":[],"prev":{"headline":"Pear Admin Boot getDictItems sql injection","id":"CVE-2024-6241"},"products":["1756-EN2F","1756-EN2T","1756-EN2TP","1756-EN2TR","1756-EN3TR","1756-EN4TR","ControlLogix® 5580 (1756-L8z)","GuardLogix® 5580  (1756-L8zS)"],"published":"2024-08-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-09-25","vendors":["Rockwell Automation"]},"summary":"Attackers can bypass Trusted Slot restrictions to execute CIP commands that modify user projects and device configurations on Logix controllers.","url":"https://insights.sbomify.com/CVE-2024-6242/"}