{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-6344 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-6344 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-6344 is a medium-severity cross-site scripting vulnerability in ZKTeco ZKBio CVSecurity V5000, published on 26 Jun 2024. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-6344 and fix it if it is affected.\n\nWhat it is: CVE-2024-6344 is a medium-severity cross-site scripting vulnerability in ZKTeco ZKBio CVSecurity V5000, published on 26 Jun 2024. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-6344 in the wild and no public exploit code.\n\nAffected product: ZKTeco ZKBio CVSecurity V5000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-6344/ (Markdown: https://insights.sbomify.com/CVE-2024-6344/index.md)","id":"CVE-2024-6344","markdown":"https://insights.sbomify.com/CVE-2024-6344/index.md","name":"CVE-2024-6344","record":{"aliases":["GHSA-mcpx-wv4g-3hg5"],"analysis":{"component_type":"web_application","fix_type":"end_of_life","impacts":["code_execution","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"ZKTeco security software","requires_auth":"high_privilege","summary":"Remote attackers can inject malicious scripts via the Configuration Name field in ZKTeco ZKBio CVSecurity V5000, requiring migration to a supported version.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"zkbiosecurity_v5000","vendor":"zkteco"}],"cvss":{"score":4.8,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-94","name":"Improper Control of Generation of Code"},{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"A vulnerability, which was classified as problematic, was found in ZKTeco ZKBio CVSecurity V5000 4.1.0. This affects an unknown part of the component Push Configuration Section. The manipulation of the argument Configuration Name leads to cross site scripting. It is possible to initiate the attack remotely. It is recommended to upgrade the affected component. The vendor explains, that \"[s]ince ZKBio CVSecurity v5000 has been withdrawn from the market, we recommend upgrading to ZKBio CVSecurity V6600 6.1.3_R or above\". This vulnerability only affects products that are no longer supported by the maintainer.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"ZKTeco ZKBio CVSecurity V5000 Push Configuration Section cross site scripting","id":"CVE-2024-6344","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"Remote Code Execution in pypa/setuptools","id":"CVE-2024-6345"},"packages":[],"prev":{"headline":"Memory corruption in ATP series firmware","id":"CVE-2024-6343"},"products":["ZKBio CVSecurity V5000"],"published":"2024-06-26","related":[{"cvss_score":8.8,"headline":"Missing authorization in n/a","id":"CVE-2022-36634","kev_date_added":null,"published":"2022-10-07"},{"cvss_score":8.8,"headline":"SQL injection in n/a","id":"CVE-2022-36635","kev_date_added":null,"published":"2022-10-07"},{"cvss_score":5.1,"headline":"ZKTeco ZKBio CVSecurity V5000 Department Section cross site scripting","id":"CVE-2024-6005","kev_date_added":null,"published":"2024-06-15"},{"cvss_score":5.1,"headline":"ZKTeco ZKBio CVSecurity V5000 Summer Schedule cross site scripting","id":"CVE-2024-6006","kev_date_added":null,"published":"2024-06-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-07-10","vendors":["ZKTeco"]},"summary":"Remote attackers can inject malicious scripts via the Configuration Name field in ZKTeco ZKBio CVSecurity V5000, requiring migration to a supported version.","url":"https://insights.sbomify.com/CVE-2024-6344/"}