{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-6435 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-6435 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-6435 is a high-severity vulnerability in Rockwell Automation Pavilion8®, published on 16 Jul 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-6435 and fix it if it is affected.\n\nWhat it is: CVE-2024-6435 is a high-severity vulnerability in Rockwell Automation Pavilion8®, published on 16 Jul 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-6435 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation Pavilion8®. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-6435/ (Markdown: https://insights.sbomify.com/CVE-2024-6435/index.md)","id":"CVE-2024-6435","markdown":"https://insights.sbomify.com/CVE-2024-6435/index.md","name":"CVE-2024-6435","record":{"aliases":["GHSA-55x8-qm73-mrfg"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation","data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial Automation Platform","requires_auth":"low_privilege","summary":"A malicious user with basic privileges can escalate to administrative level to read sensitive data and create new users in Rockwell Automation Pavilion8.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Rockwell","cpe":[{"product":"pavilion8","vendor":"rockwellautomation"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"A privilege escalation vulnerability exists in the affected products which could allow a malicious user with basic privileges to access functions which should only be available to users with administrative level privileges. If exploited, an attacker could read sensitive data, and create users. For example, a malicious user with basic privileges could perform critical functions such as creating a user with elevated privileges and reading sensitive information in the “views” section.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Rockwell Automation Privilege Escalation Vulnerability in Pavilion8®","id":"CVE-2024-6435","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Rockwell Automation Input Validation Vulnerability exists in the SequenceManager™ Server","id":"CVE-2024-6436"},"packages":[],"prev":{"headline":"Premium Addons for Elementor \u003c= 4.10.35 - Regular Expressions Denial of Service","id":"CVE-2024-6434"},"products":["Pavilion8®"],"published":"2024-07-16","related":[{"cvss_score":8.8,"headline":"Rockwell Automation Incorrect Privileges and Path Traversal Vulnerability in Pavilion8®","id":"CVE-2024-7960","kev_date_added":null,"published":"2024-09-12"},{"cvss_score":8.8,"headline":"Pavilion8 Security Misconfiguration Vulnerability","id":"CVE-2023-29463","kev_date_added":null,"published":"2023-09-12"},{"cvss_score":8.6,"headline":"Rockwell Automation Path Traversal Vulnerability in Pavilion8®","id":"CVE-2024-7961","kev_date_added":null,"published":"2024-09-12"},{"cvss_score":5.3,"headline":"Rockwell Automation Pavilion8® Unencrypted Data Vulnerability via HTTP protocol","id":"CVE-2024-40620","kev_date_added":null,"published":"2024-08-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-08-27","vendors":["Rockwell Automation"]},"summary":"A malicious user with basic privileges can escalate to administrative level to read sensitive data and create new users in Rockwell Automation Pavilion8.","url":"https://insights.sbomify.com/CVE-2024-6435/"}