{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-6981 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-6981 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-6981 is a critical missing authorization vulnerability in OMNTEC Proteus Tank Monitoring, published on 27 Sep 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-6981 and fix it if it is affected.\n\nWhat it is: CVE-2024-6981 is a critical missing authorization vulnerability in OMNTEC Proteus Tank Monitoring, published on 27 Sep 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-6981 in the wild and no public exploit code.\n\nAffected product: OMNTEC Proteus Tank Monitoring. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-6981/ (Markdown: https://insights.sbomify.com/CVE-2024-6981/index.md)","id":"CVE-2024-6981","markdown":"https://insights.sbomify.com/CVE-2024-6981/index.md","name":"CVE-2024-6981","record":{"aliases":["GHSA-pq82-r7vq-hfqh"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["privilege_escalation","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Tank monitoring system","requires_auth":"none","summary":"Attackers can perform administrative actions on OMNTEC Proteus Tank Monitoring systems without authentication, risking unauthorized control.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"OMNTEC Proteus Tank Monitoring OEL8000III Series\n\ncould allow an attacker to perform administrative actions without proper authentication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"OMNTEC Proteus Tank Monitoring Missing Authentication for Critical Function","id":"CVE-2024-6981","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Remote Code Execution in Calculate Function in parisneo/lollms","id":"CVE-2024-6982"},"packages":[],"prev":{"headline":"Verbose error handling issue in GravityZone Update Server proxy service","id":"CVE-2024-6980"},"products":["Proteus Tank Monitoring"],"published":"2024-09-27","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-09-27","vendors":["OMNTEC"]},"summary":"Attackers can perform administrative actions on OMNTEC Proteus Tank Monitoring systems without authentication, risking unauthorized control.","url":"https://insights.sbomify.com/CVE-2024-6981/"}