{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2024-7408 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-7408 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-7408 is a high-severity vulnerability in Airveda Air Quality Monitor PM2.5 PM10, published on 9 Aug 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-7408 and fix it if it is affected.\n\nWhat it is: CVE-2024-7408 is a high-severity vulnerability in Airveda Air Quality Monitor PM2.5 PM10, published on 9 Aug 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-7408 in the wild and no public exploit code.\n\nAffected product: Airveda Air Quality Monitor PM2.5 PM10. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-7408/ (Markdown: https://insights.sbomify.com/CVE-2024-7408/index.md)","id":"CVE-2024-7408","markdown":"https://insights.sbomify.com/CVE-2024-7408/index.md","name":"CVE-2024-7408","record":{"aliases":["GHSA-3wvg-3mmq-332j"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Air Quality Monitor","requires_auth":"none","summary":"Attackers can capture sensitive data during Wi-Fi pairing to perform Evil Twin attacks on Airveda Air Quality Monitors.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERT-In","cpe":[{"product":"pm2.5_pm10_monitor_firmware","vendor":"airveda"}],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.\n\nSuccessful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information Disclosure Vulnerability in Airveda Air Quality Monitor","id":"CVE-2024-7408","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Qemu: denial of service via improper synchronization in qemu nbd server during socket closure","id":"CVE-2024-7409"},"packages":[],"prev":{"headline":"Weak password encoding in Streamsoft Prestiż","id":"CVE-2024-7407"},"products":["Air Quality Monitor PM2.5 PM10"],"published":"2024-08-09","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-08-09","vendors":["Airveda"]},"summary":"Attackers can capture sensitive data during Wi-Fi pairing to perform Evil Twin attacks on Airveda Air Quality Monitors.","url":"https://insights.sbomify.com/CVE-2024-7408/"}