{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-7707 exists.","fix":"No fix has been published for CVE-2024-7707 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-7707 is a high-severity memory corruption vulnerability in Tenda FH1206, published on 13 Aug 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-7707 and fix it if it is affected.\n\nWhat it is: CVE-2024-7707 is a high-severity memory corruption vulnerability in Tenda FH1206, published on 13 Aug 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-7707 exists.\n\nAffected product: Tenda FH1206. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-7707/ (Markdown: https://insights.sbomify.com/CVE-2024-7707/index.md)","id":"CVE-2024-7707","markdown":"https://insights.sbomify.com/CVE-2024-7707/index.md","name":"CVE-2024-7707","record":{"aliases":["GHSA-gqg7-4h7v-f4hf"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda FH1206 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda FH1206 router via a crafted HTTP POST request, potentially leading to code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"fh1206_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda FH1206 HTTP POST Request SafeEmailFilter formSafeEmailFilter stack-based overflow","id":"CVE-2024-7707","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"Eclipse Jetty: DoS attack triggering OutOfMemory with 100-Continue requests","id":"CVE-2024-7708"},"packages":[],"prev":{"headline":"Fujian mwcms uploadfile.html uploadimage unrestricted upload","id":"CVE-2024-7706"},"products":["FH1206"],"published":"2024-08-13","related":[{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-42978","kev_date_added":null,"published":"2024-08-15"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-35339","kev_date_added":null,"published":"2024-05-24"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-34943","kev_date_added":null,"published":"2024-05-10"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-34945","kev_date_added":null,"published":"2024-05-10"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-33215","kev_date_added":null,"published":"2024-04-23"},{"cvss_score":8.8,"headline":"Memory corruption in n/a","id":"CVE-2024-34942","kev_date_added":null,"published":"2024-05-10"},{"cvss_score":8.8,"headline":"Memory corruption in n/a","id":"CVE-2024-34944","kev_date_added":null,"published":"2024-05-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-08-14","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda FH1206 router via a crafted HTTP POST request, potentially leading to code execution.","url":"https://insights.sbomify.com/CVE-2024-7707/"}