{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-8232 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-8232 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-8232 is a high-severity vulnerability in iniNet Solutions GmbH SpiderControl SCADA Web Server, published on 10 Sep 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-8232 and fix it if it is affected.\n\nWhat it is: CVE-2024-8232 is a high-severity vulnerability in iniNet Solutions GmbH SpiderControl SCADA Web Server, published on 10 Sep 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-8232 in the wild and no public exploit code.\n\nAffected product: iniNet Solutions GmbH SpiderControl SCADA Web Server. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-8232/ (Markdown: https://insights.sbomify.com/CVE-2024-8232/index.md)","id":"CVE-2024-8232","markdown":"https://insights.sbomify.com/CVE-2024-8232/index.md","name":"CVE-2024-8232","record":{"aliases":["GHSA-rqjx-229x-7jmc"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA web server","requires_auth":"none","summary":"Attackers can upload malicious files to the SCADA web server without authentication, potentially leading to code execution.","user_interaction":"not_required","vuln_class":"file_upload"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-434","name":"Unrestricted Upload of File with Dangerous Type"}],"description":"SpiderControl SCADA Web Server has a vulnerability that could allow an \nattacker to upload specially crafted malicious files without \nauthentication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":"2025-06-12","github_poc":1,"max_poc_stars":0,"metasploit":0,"nuclei":0,"refs":[{"date":"2025-06-12T07:44:56Z","kind":"github_poc","ref":"https://github.com/z3usx01/CVE-2024-8232","stars":0,"title":"SpiderControl SCADA Web Server File Upload Vulnerability"}],"tier":"poc_unverified"},"has_fix":null,"headline":"iniNet Solutions SpiderControl SCADA Web Server Unrestricted Upload of File with Dangerous Type","id":"CVE-2024-8232","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"file_upload","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Inefficient Algorithmic Complexity in GitLab","id":"CVE-2024-8233"},"packages":[],"prev":{"headline":"Tenda O6 setPortForward fromVirtualSet stack-based overflow","id":"CVE-2024-8231"},"products":["SpiderControl SCADA Web Server"],"published":"2024-09-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"open","licence":"CC0","name":"PoC-in-GitHub"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-09-12","vendors":["iniNet Solutions GmbH"]},"summary":"Attackers can upload malicious files to the SCADA web server without authentication, potentially leading to code execution.","url":"https://insights.sbomify.com/CVE-2024-8232/"}