{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2024-8306 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-8306 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-8306 is a high-severity vulnerability in Schneider Electric Vijeo Designer, published on 11 Sep 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-8306 and fix it if it is affected.\n\nWhat it is: CVE-2024-8306 is a high-severity vulnerability in Schneider Electric Vijeo Designer, published on 11 Sep 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-8306 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Vijeo Designer. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-8306/ (Markdown: https://insights.sbomify.com/CVE-2024-8306/index.md)","id":"CVE-2024-8306","markdown":"https://insights.sbomify.com/CVE-2024-8306/index.md","name":"CVE-2024-8306","record":{"aliases":["GHSA-q9c5-cgr2-rx6v"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["privilege_escalation","data_read","data_modify","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCADA design software","requires_auth":"low_privilege","summary":"Authenticated non-admin users can escalate privileges by tampering with binaries, compromising workstation confidentiality, integrity, and availability.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"vijeo_designer","vendor":"schneider-electric"},{"product":"vijeo_designer_embedded_in_ecostruxure_machine_expert","vendor":"schneider-electric"}],"cvss":{"score":7.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-269","name":"Improper Privilege Management"}],"description":"CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized\naccess, loss of confidentiality, integrity and availability of the workstation when non-admin\nauthenticated user tries to perform privilege escalation by tampering with the binaries.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in Vijeo Designer","id":"CVE-2024-8306","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Siempelkamp: SQL injection due to improper handling of HTTP request input data","id":"CVE-2024-8308"},"packages":[],"prev":{"headline":"MongoDB Server secondaries may crash due to forced index constraints","id":"CVE-2024-8305"},"products":["Vijeo Designer","Vijeo Designer embedded in EcoStruxure™ Machine Expert"],"published":"2024-09-11","related":[{"cvss_score":8.8,"headline":"Hardcoded credentials in Vijeo Designer Basic (V1.1 HotFix 16 and prior) and Vijeo Designer (V6.2 SP9 and prior)","id":"CVE-2020-7501","kev_date_added":null,"published":"2020-06-16"},{"cvss_score":7.8,"headline":"Code injection in Vijeo Designer Basic (V1.1 HotFix 15 and prior) and Vijeo Designer (V6.9 SP9 and prior)","id":"CVE-2020-7490","kev_date_added":null,"published":"2020-04-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2024-09-11","vendors":["Schneider Electric"]},"summary":"Authenticated non-admin users can escalate privileges by tampering with binaries, compromising workstation confidentiality, integrity, and availability.","url":"https://insights.sbomify.com/CVE-2024-8306/"}