{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-8401 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-8401 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-8401 is a medium-severity cross-site scripting vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert (PME) 2020, published on 28 Jan 2025. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-8401 and fix it if it is affected.\n\nWhat it is: CVE-2024-8401 is a medium-severity cross-site scripting vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert (PME) 2020, published on 28 Jan 2025. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-8401 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Power Monitoring Expert (PME) 2020. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-8401/ (Markdown: https://insights.sbomify.com/CVE-2024-8401/index.md)","id":"CVE-2024-8401","markdown":"https://insights.sbomify.com/CVE-2024-8401/index.md","name":"CVE-2024-8401","record":{"aliases":["GHSA-vqxv-7634-4c22"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Power Monitoring Expert","requires_auth":"low_privilege","summary":"An authenticated attacker can inject malicious scripts via folder names in Schneider Electric power monitoring software, potentially compromising user sessions.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":5.4,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"CWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’)\nvulnerability exists when an authenticated attacker modifies folder names within the context of\nthe product.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in EcoStruxure Power Monitoring Expert (PME) 2020","id":"CVE-2024-8401","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"Improper Neutralization of Special Elements used in a Command ('Command Injection') in GitLab","id":"CVE-2024-8402"},"packages":[],"prev":{"headline":"Stored XSS in gaizhenbiao/chuanhuchatgpt","id":"CVE-2024-8400"},"products":["EcoStruxure Power Monitoring Expert (PME) 2020","EcoStruxure Power Monitoring Expert (PME) 2021","EcoStruxure Power Operation (EPO) 2021","EcoStruxure Power Operation (EPO) 2021 – Advanced Reporting and Dashboards Module","EcoStruxure Power Operation (EPO) 2022","EcoStruxure Power Operation (EPO) 2022 – Advanced Reporting and Dashboards Module","EcoStruxure Power SCADA Operation 2020 (PSO) - Advanced Reporting and Dashboards Module"],"published":"2025-01-28","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-01-28","vendors":["Schneider Electric"]},"summary":"An authenticated attacker can inject malicious scripts via folder names in Schneider Electric power monitoring software, potentially compromising user sessions.","url":"https://insights.sbomify.com/CVE-2024-8401/"}