{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-8705 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-8705 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-8705 is a medium-severity SQL injection vulnerability in Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System, published on 11 Sep 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-8705 and fix it if it is affected.\n\nWhat it is: CVE-2024-8705 is a medium-severity SQL injection vulnerability in Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System, published on 11 Sep 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-8705 in the wild and no public exploit code.\n\nAffected product: Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-8705/ (Markdown: https://insights.sbomify.com/CVE-2024-8705/index.md)","id":"CVE-2024-8705","markdown":"https://insights.sbomify.com/CVE-2024-8705/index.md","name":"CVE-2024-8705","record":{"aliases":["GHSA-gxc7-4j9m-mpjc"],"analysis":{"component_type":"web_application","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Heating Network Monitoring System","requires_auth":"low_privilege","summary":"Remote attackers can exploit SQL injection in the heating network monitoring system to read or modify database contents.","user_interaction":"not_required","vuln_class":"sql_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command"}],"description":"A vulnerability was found in Shandong Star Measurement and Control Equipment Heating Network Wireless Monitoring System 5.6.2 and classified as critical. Affected by this issue is the function GetDataKindByType of the file /DataSrvs/UCCGSrv.asmx. The manipulation leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"SQL injection in Heating Network Wireless Monitoring System","id":"CVE-2024-8705","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"sql_injection","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"JFinalCMS com.cms.util.TemplateUtils update path traversal","id":"CVE-2024-8706"},"packages":[],"prev":{"headline":"Advanced File Manager \u003c= 5.2.8 - Authenticated (Administrator+) Local JavaScript File Inclusion via fma_locale","id":"CVE-2024-8704"},"products":["Heating Network Wireless Monitoring System"],"published":"2024-09-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-09-12","vendors":["Shandong Star Measurement and Control Equipment"]},"summary":"Remote attackers can exploit SQL injection in the heating network monitoring system to read or modify database contents.","url":"https://insights.sbomify.com/CVE-2024-8705/"}