{"answers":{"affected":"It affects 2 products.","exploited":"Yes. Attackers have exploited CVE-2024-8956 in the wild since at least 4 Nov 2024.","fix":"No fix has been published for CVE-2024-8956 yet. Limit exposure of the affected software until one is available. US federal agencies must fix it by 25 Nov 2024.","what":"CVE-2024-8956 is a critical missing authorization vulnerability in PTZOptics PT30X-NDI, published on 17 Sep 2024. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-8956 and fix it if it is affected.\n\nWhat it is: CVE-2024-8956 is a critical missing authorization vulnerability in PTZOptics PT30X-NDI, published on 17 Sep 2024. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: Yes. Attackers have exploited CVE-2024-8956 in the wild since at least 4 Nov 2024.\n\nAffected product: PTZOptics PT30X-NDI. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-8956/ (Markdown: https://insights.sbomify.com/CVE-2024-8956/index.md)","id":"CVE-2024-8956","markdown":"https://insights.sbomify.com/CVE-2024-8956/index.md","name":"CVE-2024-8956","record":{"aliases":["GHSA-58rw-8pf6-2mgq"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"PTZOptics camera","requires_auth":"none","summary":"Remote attackers can access sensitive configuration data and modify settings on PTZOptics cameras due to missing authentication checks on a specific endpoint.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[{"product":"pt30x-ndi-xx-g2_firmware","vendor":"ptzoptics"},{"product":"pt30x-sdi_firmware","vendor":"ptzoptics"}],"cvss":{"score":9.1,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"},{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"exploited"},"has_fix":null,"headline":"PTZOptics PT30X-SDI/NDI Cameras Authentication Bypass","id":"CVE-2024-8956","indexable":true,"kev":{"dateAdded":"2024-11-04","dueDate":"2024-11-25","knownRansomwareCampaignUse":"Unknown","product":"PT30X-SDI/NDI Cameras","requiredAction":"Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.","vendorProject":"PTZOptics","vulnerabilityName":"PTZOptics PT30X-SDI/NDI Cameras Authentication Bypass Vulnerability"},"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2024"},"n_packages":0,"n_references":2,"next":{"headline":"PTZOptics PT30X-SDI/NDI Cameras OS Command Injection","id":"CVE-2024-8957"},"packages":[],"prev":{"headline":"SSRF in composiohq/composio","id":"CVE-2024-8955"},"products":["PT30X-NDI","PT30X-SDI"],"published":"2024-09-17","related":[{"cvss_score":7.2,"headline":"PTZOptics PT30X-SDI/NDI Cameras OS Command Injection","id":"CVE-2024-8957","kev_date_added":"2024-11-04","published":"2024-09-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"open","licence":"CC0 1.0","name":"CISA KEV"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"active","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-11-22","vendors":["PTZOptics"]},"summary":"Remote attackers can access sensitive configuration data and modify settings on PTZOptics cameras due to missing authentication checks on a specific endpoint.","url":"https://insights.sbomify.com/CVE-2024-8956/"}