{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-9005 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-9005 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-9005 is a high-severity unsafe deserialization vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert (PME), published on 8 Oct 2024. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2024-9005 and fix it if it is affected.\n\nWhat it is: CVE-2024-9005 is a high-severity unsafe deserialization vulnerability in Schneider Electric EcoStruxure Power Monitoring Expert (PME), published on 8 Oct 2024. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2024-9005 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Power Monitoring Expert (PME). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-9005/ (Markdown: https://insights.sbomify.com/CVE-2024-9005/index.md)","id":"CVE-2024-9005","markdown":"https://insights.sbomify.com/CVE-2024-9005/index.md","name":"CVE-2024-9005","record":{"aliases":["GHSA-h25j-66v8-m35v"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Power Monitoring Expert","requires_auth":"low_privilege","summary":"Remote attackers can execute arbitrary code on Schneider Electric EcoStruxure Power Monitoring Expert servers by sending maliciously serialized data.","user_interaction":"required","vuln_class":"deserialization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":7.3,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-502","name":"Deserialization of Untrusted Data"}],"description":"CWE-502: Deserialization of Untrusted Data vulnerability exists that could allow code to be\nremotely executed on the server when unsafely deserialized data is posted to the web server.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Deserialization in EcoStruxure Power Monitoring Expert (PME)","id":"CVE-2024-9005","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"deserialization","year":"2024"},"n_packages":0,"n_references":1,"next":{"headline":"jeanmarc77 123solar config_invt1.php code injection","id":"CVE-2024-9006"},"packages":[],"prev":{"headline":"D-Link DAR-7000 Backup_Server_commit.php os command injection","id":"CVE-2024-9004"},"products":["EcoStruxure Power Monitoring Expert (PME)"],"published":"2024-10-08","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-03-25","vendors":["Schneider Electric"]},"summary":"Remote attackers can execute arbitrary code on Schneider Electric EcoStruxure Power Monitoring Expert servers by sending maliciously serialized data.","url":"https://insights.sbomify.com/CVE-2024-9005/"}