{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-9275 exists.","fix":"No fix has been published for CVE-2024-9275 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-9275 is a medium-severity path traversal vulnerability in jeanmarc77 123solar, published on 27 Sep 2024. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-9275 and fix it if it is affected.\n\nWhat it is: CVE-2024-9275 is a medium-severity path traversal vulnerability in jeanmarc77 123solar, published on 27 Sep 2024. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2024-9275 exists.\n\nAffected product: jeanmarc77 123solar. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-9275/ (Markdown: https://insights.sbomify.com/CVE-2024-9275/index.md)","id":"CVE-2024-9275","markdown":"https://insights.sbomify.com/CVE-2024-9275/index.md","name":"CVE-2024-9275","record":{"aliases":["GHSA-p6qp-r9qf-v2m7"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["code_execution","data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"123solar web application","requires_auth":"low_privilege","summary":"Remote attackers can exploit a file inclusion vulnerability in 123solar to execute arbitrary code or read sensitive files.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-73","name":"External Control of File Name or Path"}],"description":"A vulnerability was found in jeanmarc77 123solar up to 1.8.4.5. It has been rated as critical. This issue affects some unknown processing of the file /admin/admin_invt2.php. The manipulation of the argument PROTOCOLx leads to file inclusion. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":false,"headline":"jeanmarc77 123solar admin_invt2.php file inclusion","id":"CVE-2024-9275","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2024"},"n_packages":0,"n_references":4,"next":{"headline":"TMsoft MyAuth Gateway index.php cross site scripting","id":"CVE-2024-9276"},"packages":[],"prev":{"headline":"Elastik Page Builder \u003c= 0.27.4 - Authenticated (Author+) Stored Cross-Site Scripting via SVG File Upload","id":"CVE-2024-9274"},"products":["123solar"],"published":"2024-09-27","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2024-09-27","vendors":["jeanmarc77"]},"summary":"Remote attackers can exploit a file inclusion vulnerability in 123solar to execute arbitrary code or read sensitive files.","url":"https://insights.sbomify.com/CVE-2024-9275/"}