{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2024-9852 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2024-9852 yet. Limit exposure of the affected software until one is available.","what":"CVE-2024-9852 is a high-severity vulnerability in Mitsubishi Electric Corporation GENESIS32, published on 28 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2024-9852 and fix it if it is affected.\n\nWhat it is: CVE-2024-9852 is a high-severity vulnerability in Mitsubishi Electric Corporation GENESIS32, published on 28 Nov 2024. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2024-9852 in the wild and no public exploit code.\n\nAffected product: Mitsubishi Electric Corporation GENESIS32. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2024-9852/ (Markdown: https://insights.sbomify.com/CVE-2024-9852/index.md)","id":"CVE-2024-9852","markdown":"https://insights.sbomify.com/CVE-2024-9852/index.md","name":"CVE-2024-9852","record":{"aliases":["GHSA-grq9-8qm8-vhjr"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution","data_read","data_modify","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SCADA software","requires_auth":"low_privilege","summary":"Local attackers can execute malicious code via DLL hijacking in Mitsubishi SCADA products, leading to data compromise or denial of service.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Mitsubishi","cpe":[],"cvss":{"score":7.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-427","name":"Uncontrolled Search Path Element"}],"description":"Uncontrolled Search Path Element vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 all versions, Mitsubishi Electric MC Works64 all versions, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions Hyper Historian versions 10.97.3 and prior, and Mitsubishi Electric Iconics Digital Solutions GENESIS32 all versions allows a local authenticated attacker to execute a malicious code by storing a specially crafted DLL in a specific folder. This could lead to disclose, tamper with, destroy, or delete information in the affected products, or cause a denial of service (DoS) condition on the products.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Malicious Code Execution Vulnerability in GENESIS64, ICONICS Suite, Hyper Historian, MC Works64, and GENESIS32","id":"CVE-2024-9852","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2024"},"n_packages":0,"n_references":3,"next":{"headline":"ID-SK Toolkit \u003c= 1.7.2 - Authenticated (Author+) Stored Cross-Site Scripting via SVG File Upload","id":"CVE-2024-9853"},"packages":[],"prev":{"headline":"LSX Tour Operator \u003c= 1.4.9 - Authenticated (Author+) Stored Cross-Site Scripting via SVG File Upload","id":"CVE-2024-9851"},"products":["GENESIS32","GENESIS64","Hyper Historian","ICONICS Suite","MC Works64"],"published":"2024-11-28","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-04-08","vendors":["Mitsubishi Electric Corporation","Mitsubishi Electric Iconics Digital Solutions"]},"summary":"Local attackers can execute malicious code via DLL hijacking in Mitsubishi SCADA products, leading to data compromise or denial of service.","url":"https://insights.sbomify.com/CVE-2024-9852/"}