{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-0349 exists.","fix":"No fix has been published for CVE-2025-0349 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-0349 is a high-severity memory corruption vulnerability in Tenda Ac6 Firmware, published on 9 Jan 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-0349 and fix it if it is affected.\n\nWhat it is: CVE-2025-0349 is a high-severity memory corruption vulnerability in Tenda Ac6 Firmware, published on 9 Jan 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-0349 exists.\n\nAffected product: Tenda Ac6 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-0349/ (Markdown: https://insights.sbomify.com/CVE-2025-0349/index.md)","id":"CVE-2025-0349","markdown":"https://insights.sbomify.com/CVE-2025-0349/index.md","name":"CVE-2025-0349","record":{"aliases":["GHSA-5r5h-j8r7-pr7g"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC6 router","requires_auth":"low_privilege","summary":"A remote attacker can trigger a stack-based buffer overflow in the Tenda AC6 router via the GetParentControlInfo endpoint, potentially leading to code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac6_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"},{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability classified as critical has been found in Tenda AC6 15.03.05.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src/mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC6 GetParentControlInfo stack-based overflow","id":"CVE-2025-0349","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac6_firmware","products":["tenda:ac6_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"Cross-site scripting in Divi Carousel Free (Divi5 Support)","id":"CVE-2025-0350"},"packages":[],"prev":{"headline":"CampCodes DepEd Equipment Inventory System add_employee.php cross site scripting","id":"CVE-2025-0348"},"products":["AC6"],"published":"2025-01-09","related":[{"cvss_score":9.8,"headline":"Auth bypass in AC6 V5.0","id":"CVE-2025-27129","kev_date_added":null,"published":"2025-08-20"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29029","kev_date_added":null,"published":"2025-03-14"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29030","kev_date_added":null,"published":"2025-03-14"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29031","kev_date_added":null,"published":"2025-03-14"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25343","kev_date_added":null,"published":"2025-02-12"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-40830","kev_date_added":null,"published":"2023-10-03"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2023-40837","kev_date_added":null,"published":"2023-08-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-03-22","vendors":["Tenda"]},"summary":"A remote attacker can trigger a stack-based buffer overflow in the Tenda AC6 router via the GetParentControlInfo endpoint, potentially leading to code execution.","url":"https://insights.sbomify.com/CVE-2025-0349/"}