CVE-2025-0593 SICK Lector8xx and InspectorP8xx vulnerable for code execution
Remote low-privileged attackers can execute arbitrary shell commands on SICK Lector8xx and InspectorP8xx devices via lower-level functions.
- Exploited in the wild
- Not known
- Login needed
- Any signed-in user
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- None listed
What is CVE-2025-0593?
CVE-2025-0593 is a high-severity command injection vulnerability in SICK InspectorP8xx, published on 14 Feb 2025. Any signed-in user can exploit it over the network, with no action from the victim.
Official description
The vulnerability may allow a remote low priviledged attacker to run arbitrary shell commands by using lower-level functions to interact with the device.
Weakness: CWE-77
Which versions are affected by CVE-2025-0593?
How do I fix CVE-2025-0593?
No fix has been published for CVE-2025-0593 yet. Limit exposure of the affected software until one is available.
Upgrade, and pass arguments to programs as a list instead of through a shell. More about Command injection.
Is CVE-2025-0593 being exploited?
There is no known exploitation of CVE-2025-0593 in the wild and no public exploit code.
Sources
Also known as GHSA-4hj2-83vx-rh57.