{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-0626 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-0626 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-0626 is a high-severity vulnerability in Contec Health CMS8000 Patient Monitor, published on 30 Jan 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-0626 and fix it if it is affected.\n\nWhat it is: CVE-2025-0626 is a high-severity vulnerability in Contec Health CMS8000 Patient Monitor, published on 30 Jan 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-0626 in the wild and no public exploit code.\n\nAffected product: Contec Health CMS8000 Patient Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-0626/ (Markdown: https://insights.sbomify.com/CVE-2025-0626/index.md)","id":"CVE-2025-0626","markdown":"https://insights.sbomify.com/CVE-2025-0626/index.md","name":"CVE-2025-0626","record":{"aliases":["GHSA-p2j3-fm26-85wv"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Patient Monitor","requires_auth":"none","summary":"A hidden backdoor in the patient monitor firmware allows attackers to bypass network settings and upload files, potentially leading to code execution.","user_interaction":"required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":7.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-912","name":"Hidden Functionality"}],"description":"The \"monitor\" binary in the firmware of the affected product attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function also enables the network interface of the device if it is disabled. The function is triggered by attempting to update the device from the user menu. This could serve as a backdoor to the device, and could lead to a malicious actor being able to upload and overwrite files on the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hidden Functionality vulnerability in Contec Health CMS8000 Patient Monitor","id":"CVE-2025-0626","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"AI Autotagger \u003c 3.30.0 - Admin+ Stored XSS","id":"CVE-2025-0627"},"packages":[],"prev":{"headline":"CampCodes School Management Software Attachment resource injection","id":"CVE-2025-0625"},"products":["CMS8000 Patient Monitor"],"published":"2025-01-30","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-03-01","vendors":["Contec Health"]},"summary":"A hidden backdoor in the patient monitor firmware allows attackers to bypass network settings and upload files, potentially leading to code execution.","url":"https://insights.sbomify.com/CVE-2025-0626/"}