{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-0683 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-0683 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-0683 is a high-severity vulnerability in Contec Health CMS8000 Patient Monitor, published on 30 Jan 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-0683 and fix it if it is affected.\n\nWhat it is: CVE-2025-0683 is a high-severity vulnerability in Contec Health CMS8000 Patient Monitor, published on 30 Jan 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-0683 in the wild and no public exploit code.\n\nAffected product: Contec Health CMS8000 Patient Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-0683/ (Markdown: https://insights.sbomify.com/CVE-2025-0683/index.md)","id":"CVE-2025-0683","markdown":"https://insights.sbomify.com/CVE-2025-0683/index.md","name":"CVE-2025-0683","record":{"aliases":["GHSA-h39w-8pq5-8qh2"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Patient Monitor","requires_auth":"none","summary":"Patient monitors leak confidential data to a hardcoded public IP in default configuration, exposing sensitive information to attackers.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-359","name":"Exposure of Private Personal Information to an Unauthorized Actor"}],"description":"In its default configuration, Contec Health CMS8000 Patient Monitor transmits plain-text \npatient data to a hard-coded public IP address when a patient is hooked \nup to the monitor. This could lead to a leakage of confidential patient \ndata to any device with that IP address or an attacker in a \nmachine-in-the-middle scenario.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in CMS8000 Patient Monitor","id":"CVE-2025-0683","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Grub2: reiserfs: integer overflow when handling symlinks may lead to heap based out-of-bounds write when reading data","id":"CVE-2025-0684"},"packages":[],"prev":{"headline":"ThemeREX Addons \u003c= 2.33.0 - Authenticated (Contributor+) Local File Inclusion via Shortcode","id":"CVE-2025-0682"},"products":["CMS8000 Patient Monitor"],"published":"2025-01-30","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-12","vendors":["Contec Health"]},"summary":"Patient monitors leak confidential data to a hardcoded public IP in default configuration, exposing sensitive information to attackers.","url":"https://insights.sbomify.com/CVE-2025-0683/"}