{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-0813 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-0813 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-0813 is a high-severity authentication bypass vulnerability in Schneider Electric EcoStruxure Power Automation System User Interface (EPAS-UI) - Secured Versions, published on 12 Mar 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-0813 and fix it if it is affected.\n\nWhat it is: CVE-2025-0813 is a high-severity authentication bypass vulnerability in Schneider Electric EcoStruxure Power Automation System User Interface (EPAS-UI) - Secured Versions, published on 12 Mar 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-0813 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Power Automation System User Interface (EPAS-UI) - Secured Versions. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-0813/ (Markdown: https://insights.sbomify.com/CVE-2025-0813/index.md)","id":"CVE-2025-0813","markdown":"https://insights.sbomify.com/CVE-2025-0813/index.md","name":"CVE-2025-0813","record":{"aliases":["GHSA-9w79-7j73-f648"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Power Automation UI","requires_auth":"none","summary":"An attacker with physical access can bypass authentication by rebooting the EPAS-UI workstation, requiring Schneider Electric users to apply security patches.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"CWE-287: Improper Authentication vulnerability exists that could cause an Authentication Bypass when an\nunauthorized user without permission rights has physical access to the EPAS-UI computer and is able to\nreboot the workstation and interrupt the normal boot process.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in EcoStruxure Power Automation System User Interface (EPAS-UI) - Secured Versions","id":"CVE-2025-0813","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in Enerlin’X IFE interface (LV434001)","id":"CVE-2025-0814"},"packages":[],"prev":{"headline":"Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in GitLab","id":"CVE-2025-0811"},"products":["EcoStruxure Power Automation System User Interface (EPAS-UI) - Secured Versions"],"published":"2025-03-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-03-12","vendors":["Schneider Electric"]},"summary":"An attacker with physical access can bypass authentication by rebooting the EPAS-UI workstation, requiring Schneider Electric users to apply security patches.","url":"https://insights.sbomify.com/CVE-2025-0813/"}