{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-0814 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-0814 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-0814 is a medium-severity denial of service vulnerability in Schneider Electric Enerlin’X IFE interface (LV434001), published on 13 Feb 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-0814 and fix it if it is affected.\n\nWhat it is: CVE-2025-0814 is a medium-severity denial of service vulnerability in Schneider Electric Enerlin’X IFE interface (LV434001), published on 13 Feb 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-0814 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Enerlin’X IFE interface (LV434001). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-0814/ (Markdown: https://insights.sbomify.com/CVE-2025-0814/index.md)","id":"CVE-2025-0814","markdown":"https://insights.sbomify.com/CVE-2025-0814/index.md","name":"CVE-2025-0814","record":{"aliases":["GHSA-mf38-7xr2-g2q7"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial network interface","requires_auth":"none","summary":"Attackers can cause denial of service on Schneider Electric Enerlin'X interfaces by sending malicious IEC61850-MMS packets.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"CWE-20: Improper Input Validation vulnerability exists that could cause Denial-of-Service of the network\nservices running on the product when malicious IEC61850-MMS packets are sent to the device. The core\nfunctionality of the breaker remains intact during the attack.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in Enerlin’X IFE interface (LV434001)","id":"CVE-2025-0814","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in Enerlin’X IFE interface (LV434001)","id":"CVE-2025-0815"},"packages":[],"prev":{"headline":"Auth bypass in EcoStruxure Power Automation System User Interface (EPAS-UI) - Secured Versions","id":"CVE-2025-0813"},"products":["Enerlin’X IFE interface (LV434001)","Enerlin’X eIFE (LV851001)"],"published":"2025-02-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-13","vendors":["Schneider Electric"]},"summary":"Attackers can cause denial of service on Schneider Electric Enerlin'X interfaces by sending malicious IEC61850-MMS packets.","url":"https://insights.sbomify.com/CVE-2025-0814/"}