{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-10432 exists.","fix":"No fix has been published for CVE-2025-10432 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-10432 is a critical memory corruption vulnerability in Tenda AC1206, published on 15 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-10432 and fix it if it is affected.\n\nWhat it is: CVE-2025-10432 is a critical memory corruption vulnerability in Tenda AC1206, published on 15 Sep 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-10432 exists.\n\nAffected product: Tenda AC1206. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-10432/ (Markdown: https://insights.sbomify.com/CVE-2025-10432/index.md)","id":"CVE-2025-10432","markdown":"https://insights.sbomify.com/CVE-2025-10432/index.md","name":"CVE-2025-10432","record":{"aliases":["GHSA-qj3f-pj4g-wfgq"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC1206 router","requires_auth":"none","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC1206 router via the wanMTU parameter, potentially leading to code execution or service disruption.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac1206_firmware","vendor":"tenda"}],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability was found in Tenda AC1206 15.03.06.23. This vulnerability affects the function check_param_changed of the file /goform/AdvSetMacMtuWa of the component HTTP Request Handler. Performing manipulation of the argument wanMTU results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC1206 HTTP Request AdvSetMacMtuWa check_param_changed stack-based overflow","id":"CVE-2025-10432","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"1Panel-dev MaxKB debug deserialization","id":"CVE-2025-10433"},"packages":[],"prev":{"headline":"SourceCodester Pet Grooming Management Software ajax_represent.php sql injection","id":"CVE-2025-10431"},"products":["AC1206"],"published":"2025-09-15","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-37712","kev_date_added":null,"published":"2023-07-10"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2022-37798","kev_date_added":null,"published":"2022-08-25"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2022-37799","kev_date_added":null,"published":"2022-08-25"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2022-37800","kev_date_added":null,"published":"2022-08-25"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2022-37801","kev_date_added":null,"published":"2022-08-25"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2022-37802","kev_date_added":null,"published":"2022-08-25"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2022-37803","kev_date_added":null,"published":"2022-08-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-09-15","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC1206 router via the wanMTU parameter, potentially leading to code execution or service disruption.","url":"https://insights.sbomify.com/CVE-2025-10432/"}