{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-10504 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-10504 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-10504 is a medium-severity memory corruption vulnerability in ABB Terra AC wallbox, published on 29 Sep 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-10504 and fix it if it is affected.\n\nWhat it is: CVE-2025-10504 is a medium-severity memory corruption vulnerability in ABB Terra AC wallbox, published on 29 Sep 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-10504 in the wild and no public exploit code.\n\nAffected product: ABB Terra AC wallbox. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-10504/ (Markdown: https://insights.sbomify.com/CVE-2025-10504/index.md)","id":"CVE-2025-10504","markdown":"https://insights.sbomify.com/CVE-2025-10504/index.md","name":"CVE-2025-10504","record":{"aliases":["GHSA-j5wc-gp95-6rjq"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution","denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"EV charging wallbox","requires_auth":"high_privilege","summary":"Heap-based buffer overflow in ABB Terra AC wallbox allows attackers to execute arbitrary code or cause denial of service.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ABB","cpe":[],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:A/V:D/RE:L","version":"4.0"},"cwes":[{"id":"CWE-122","name":"Heap-based Buffer Overflow"}],"description":"Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Heap Memory Corruption Vulnerability","id":"CVE-2025-10504","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Sandbox escape due to use-after-free in the Graphics: Canvas2D component","id":"CVE-2025-10527"},"packages":[],"prev":{"headline":"Reflected Cross-Site Scripting via Authentication Endpoint in WSO2 Identity Server","id":"CVE-2025-10503"},"products":["Terra AC wallbox"],"published":"2025-09-29","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-10-16","vendors":["ABB"]},"summary":"Heap-based buffer overflow in ABB Terra AC wallbox allows attackers to execute arbitrary code or cause denial of service.","url":"https://insights.sbomify.com/CVE-2025-10504/"}