{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-1059 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-1059 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-1059 is a high-severity denial of service vulnerability in Schneider Electric ASCO 5310 Single-Channel Remote Annunciator, published on 13 Feb 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-1059 and fix it if it is affected.\n\nWhat it is: CVE-2025-1059 is a high-severity denial of service vulnerability in Schneider Electric ASCO 5310 Single-Channel Remote Annunciator, published on 13 Feb 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-1059 in the wild and no public exploit code.\n\nAffected product: Schneider Electric ASCO 5310 Single-Channel Remote Annunciator. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-1059/ (Markdown: https://insights.sbomify.com/CVE-2025-1059/index.md)","id":"CVE-2025-1059","markdown":"https://insights.sbomify.com/CVE-2025-1059/index.md","name":"CVE-2025-1059","record":{"aliases":["GHSA-rvvq-vmff-393g"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Remote Annunciator","requires_auth":"none","summary":"Malicious packets sent to the webserver of Schneider Electric remote annunciators can cause communications to stop, resulting in a denial of service.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-770","name":"Allocation of Resources Without Limits or Throttling"}],"description":"CWE-770: Allocation of Resources Without Limits or Throttling vulnerability exists that could\ncause communications to stop when malicious packets are sent to the webserver of the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in ASCO 5310 Single-Channel Remote Annunciator","id":"CVE-2025-1059","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in ASCO 5310 Single-Channel Remote Annunciator","id":"CVE-2025-1060"},"packages":[],"prev":{"headline":"Supply chain in ASCO 5310 Single-Channel Remote Annunciator","id":"CVE-2025-1058"},"products":["ASCO 5310 Single-Channel Remote Annunciator","ASCO 5350 Eight Channel Remote Annunciator"],"published":"2025-02-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-13","vendors":["Schneider Electric"]},"summary":"Malicious packets sent to the webserver of Schneider Electric remote annunciators can cause communications to stop, resulting in a denial of service.","url":"https://insights.sbomify.com/CVE-2025-1059/"}