{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-11009 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-11009 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-11009 is a medium-severity vulnerability in Mitsubishi Electric Corporation GT Designer3 Version1 (GOT1000), published on 17 Dec 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-11009 and fix it if it is affected.\n\nWhat it is: CVE-2025-11009 is a medium-severity vulnerability in Mitsubishi Electric Corporation GT Designer3 Version1 (GOT1000), published on 17 Dec 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-11009 in the wild and no public exploit code.\n\nAffected product: Mitsubishi Electric Corporation GT Designer3 Version1 (GOT1000). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-11009/ (Markdown: https://insights.sbomify.com/CVE-2025-11009/index.md)","id":"CVE-2025-11009","markdown":"https://insights.sbomify.com/CVE-2025-11009/index.md","name":"CVE-2025-11009","record":{"aliases":["GHSA-wcjp-gpp5-94xv"],"analysis":{"component_type":"desktop_application","fix_type":"no_fix_stated","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"HMI configuration software","requires_auth":"none","summary":"Local attackers can extract plaintext credentials from project files in Mitsubishi GT Designer3, enabling unauthorized access to GOT HMI devices.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Mitsubishi","cpe":[],"cvss":{"score":5.1,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-312","name":"Cleartext Storage of Sensitive Information"}],"description":"Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GT Designer3 Version1 (GOT2000) all versions and Mitsubishi Electric GT Designer3 Version1 (GOT1000) all versions allows a local unauthenticated attacker to obtain plaintext credentials from the project file for GT Designer3. This could allow the attacker to operate illegally GOT2000 series or GOT1000 series by using the obtained credentials.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information Disclosure Vulnerability in GT Designer3","id":"CVE-2025-11009","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"vstakhov libucl ucl_util.c ucl_include_common heap-based overflow","id":"CVE-2025-11010"},"packages":[],"prev":{"headline":"CE21 Suite \u003c= 2.3.1 - Unauthenticated Sensitive Information Exposure to Privilege Escalation","id":"CVE-2025-11008"},"products":["GT Designer3 Version1 (GOT1000)","GT Designer3 Version1 (GOT2000)"],"published":"2025-12-17","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-12-17","vendors":["Mitsubishi Electric Corporation"]},"summary":"Local attackers can extract plaintext credentials from project files in Mitsubishi GT Designer3, enabling unauthorized access to GOT HMI devices.","url":"https://insights.sbomify.com/CVE-2025-11009/"}