{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-11295 exists.","fix":"No fix has been published for CVE-2025-11295 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-11295 is a high-severity memory corruption vulnerability in Belkin F9K1015, published on 5 Oct 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-11295 and fix it if it is affected.\n\nWhat it is: CVE-2025-11295 is a high-severity memory corruption vulnerability in Belkin F9K1015, published on 5 Oct 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-11295 exists.\n\nAffected product: Belkin F9K1015. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-11295/ (Markdown: https://insights.sbomify.com/CVE-2025-11295/index.md)","id":"CVE-2025-11295","markdown":"https://insights.sbomify.com/CVE-2025-11295/index.md","name":"CVE-2025-11295","record":{"aliases":["GHSA-f32f-gp3p-9gcc"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Belkin router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a buffer overflow in the PPPoE setup interface of Belkin F9K1015 routers, potentially leading to code execution or service disruption.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"f9k1015_firmware","vendor":"belkin"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A flaw has been found in Belkin F9K1015 1.00.10. This affects an unknown part of the file /goform/formPPPoESetup. This manipulation of the argument pppUserName causes buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Belkin F9K1015 formPPPoESetup buffer overflow","id":"CVE-2025-11295","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"Belkin F9K1015 formPPTPSetup buffer overflow","id":"CVE-2025-11296"},"packages":[],"prev":{"headline":"Belkin F9K1015 formL2TPSetup buffer overflow","id":"CVE-2025-11294"},"products":["F9K1015"],"published":"2025-10-05","related":[{"cvss_score":8.7,"headline":"Belkin F9K1015 formWISP5G stack-based overflow","id":"CVE-2026-5610","kev_date_added":null,"published":"2026-04-06"},{"cvss_score":8.7,"headline":"Belkin F9K1015 formCrossBandSwitch stack-based overflow","id":"CVE-2026-5611","kev_date_added":null,"published":"2026-04-06"},{"cvss_score":8.7,"headline":"Belkin F9K1015 formWlEncrypt stack-based overflow","id":"CVE-2026-5612","kev_date_added":null,"published":"2026-04-06"},{"cvss_score":8.7,"headline":"Belkin F9K1015 formReboot stack-based overflow","id":"CVE-2026-5613","kev_date_added":null,"published":"2026-04-06"},{"cvss_score":8.7,"headline":"Belkin F9K1015 formSetPassword stack-based overflow","id":"CVE-2026-5614","kev_date_added":null,"published":"2026-04-06"},{"cvss_score":8.7,"headline":"Belkin F9K1015 Setting formSetSystemSettings stack-based overflow","id":"CVE-2026-5628","kev_date_added":null,"published":"2026-04-06"},{"cvss_score":8.7,"headline":"Belkin F9K1015 formSetFirewall stack-based overflow","id":"CVE-2026-5629","kev_date_added":null,"published":"2026-04-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-02-24","vendors":["Belkin"]},"summary":"Remote attackers can trigger a buffer overflow in the PPPoE setup interface of Belkin F9K1015 routers, potentially leading to code execution or service disruption.","url":"https://insights.sbomify.com/CVE-2025-11295/"}