{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-11325 exists.","fix":"No fix has been published for CVE-2025-11325 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-11325 is a high-severity memory corruption vulnerability in Tenda Ac18 Firmware, published on 6 Oct 2025. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-11325 and fix it if it is affected.\n\nWhat it is: CVE-2025-11325 is a high-severity memory corruption vulnerability in Tenda Ac18 Firmware, published on 6 Oct 2025. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-11325 exists.\n\nAffected product: Tenda Ac18 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-11325/ (Markdown: https://insights.sbomify.com/CVE-2025-11325/index.md)","id":"CVE-2025-11325","markdown":"https://insights.sbomify.com/CVE-2025-11325/index.md","name":"CVE-2025-11325","record":{"aliases":["GHSA-5g8h-54w4-pmjh"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC18 router","requires_auth":"low_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC18 router via the Username argument, potentially leading to code execution or service disruption.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac18_firmware","vendor":"tenda"}],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A security flaw has been discovered in Tenda AC18 15.03.05.19(6318). Affected by this issue is some unknown functionality of the file /goform/fast_setting_pppoe_set. Performing a manipulation of the argument Username results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC18 fast_setting_pppoe_set stack-based overflow","id":"CVE-2025-11325","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac18_firmware","products":["tenda:ac18_firmware"],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"Tenda AC18 WifiMacFilterSet stack-based overflow","id":"CVE-2025-11326"},"packages":[],"prev":{"headline":"Tenda AC18 setNotUpgrade stack-based overflow","id":"CVE-2025-11324"},"products":["AC18"],"published":"2025-10-06","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57575","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57579","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57580","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57581","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-57582","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2024-57583","kev_date_added":null,"published":"2025-01-16"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-33835","kev_date_added":null,"published":"2024-05-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-02-24","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda AC18 router via the Username argument, potentially leading to code execution or service disruption.","url":"https://insights.sbomify.com/CVE-2025-11325/"}