{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-11567 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-11567 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-11567 is a high-severity vulnerability in Schneider Electric PowerChute™ Serial Shutdown, published on 12 Nov 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-11567 and fix it if it is affected.\n\nWhat it is: CVE-2025-11567 is a high-severity vulnerability in Schneider Electric PowerChute™ Serial Shutdown, published on 12 Nov 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-11567 in the wild and no public exploit code.\n\nAffected product: Schneider Electric PowerChute™ Serial Shutdown. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-11567/ (Markdown: https://insights.sbomify.com/CVE-2025-11567/index.md)","id":"CVE-2025-11567","markdown":"https://insights.sbomify.com/CVE-2025-11567/index.md","name":"CVE-2025-11567","record":{"aliases":["GHSA-vr2h-fpfm-62g7"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"PowerChute Serial Shutdown","requires_auth":"low_privilege","summary":"Incorrect default permissions in the installation folder allow attackers to gain elevated system access on Schneider Electric PowerChute Serial Shutdown.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":7.3,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-276","name":"Incorrect Default Permissions"}],"description":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause elevated system access when the target installation folder is not properly secured.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in PowerChute™ Serial Shutdown","id":"CVE-2025-11567","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Luksmeta: data corruption when handling luks1 partitions with luksmeta","id":"CVE-2025-11568"},"packages":[],"prev":{"headline":"Auth bypass in PowerChute™ Serial Shutdown","id":"CVE-2025-11566"},"products":["PowerChute™ Serial Shutdown"],"published":"2025-11-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-11-12","vendors":["Schneider Electric"]},"summary":"Incorrect default permissions in the installation folder allow attackers to gain elevated system access on Schneider Electric PowerChute Serial Shutdown.","url":"https://insights.sbomify.com/CVE-2025-11567/"}