{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2025-11739 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-11739 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-11739 is a high-severity unsafe deserialization vulnerability in Schneider Electric EcoStruxure™ Power Monitoring Expert (PME), published on 10 Mar 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-11739 and fix it if it is affected.\n\nWhat it is: CVE-2025-11739 is a high-severity unsafe deserialization vulnerability in Schneider Electric EcoStruxure™ Power Monitoring Expert (PME), published on 10 Mar 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-11739 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure™ Power Monitoring Expert (PME). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-11739/ (Markdown: https://insights.sbomify.com/CVE-2025-11739/index.md)","id":"CVE-2025-11739","markdown":"https://insights.sbomify.com/CVE-2025-11739/index.md","name":"CVE-2025-11739","record":{"aliases":["GHSA-8hcj-8666-8jwh"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Power monitoring software","requires_auth":"low_privilege","summary":"A local authenticated attacker can achieve arbitrary code execution with administrative privileges via unsafe deserialization in Schneider Electric power monitoring software.","user_interaction":"not_required","vuln_class":"deserialization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_power_monitoring_expert","vendor":"schneider-electric"},{"product":"ecostruxure_power_operation","vendor":"schneider-electric"}],"cvss":{"score":8.5,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-502","name":"Deserialization of Untrusted Data"}],"description":"CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Deserialization in EcoStruxure™ Power Monitoring Expert (PME)","id":"CVE-2025-11739","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"deserialization","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"wpForo Forum \u003c= 2.4.9 - Authenticated (Susbscriber+) SQL Injection","id":"CVE-2025-11740"},"packages":[],"prev":{"headline":"Media Library Assistant \u003c= 3.29 - Unauthenticated Limited File Read","id":"CVE-2025-11738"},"products":["EcoStruxure™ Power Monitoring Expert (PME)","EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module"],"published":"2026-03-10","related":[{"cvss_score":9.8,"headline":"Deserialization in EcoStruxure Power Monitoring Expert","id":"CVE-2023-5391","kev_date_added":null,"published":"2023-10-04"},{"cvss_score":8.8,"headline":"Other in EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","id":"CVE-2022-22727","kev_date_added":null,"published":"2022-02-04"},{"cvss_score":8.8,"headline":"Code injection in n/a","id":"CVE-2021-22826","kev_date_added":null,"published":"2022-01-28"},{"cvss_score":8.8,"headline":"Code injection in n/a","id":"CVE-2021-22827","kev_date_added":null,"published":"2022-01-28"},{"cvss_score":8.2,"headline":"Open redirect in EcoStruxure Power Monitoring Expert (PME)","id":"CVE-2023-5986","kev_date_added":null,"published":"2023-11-15"},{"cvss_score":6.7,"headline":"Auth bypass in EcoStruxure Power Monitoring Expert","id":"CVE-2023-28003","kev_date_added":null,"published":"2023-04-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-03-10","vendors":["Schneider Electric"]},"summary":"A local authenticated attacker can achieve arbitrary code execution with administrative privileges via unsafe deserialization in Schneider Electric power monitoring software.","url":"https://insights.sbomify.com/CVE-2025-11739/"}