CVE-2025-11784 Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50

High 8.5 Published Updated

An attacker can trigger a stack-based buffer overflow in Circutor PLCs via excessive input, potentially leading to code execution or denial of service.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Local or same network only
Victim action needed
Not needed
Fix
None listed

What is CVE-2025-11784?

CVE-2025-11784 is a high-severity memory corruption vulnerability in SGE-PLC1000 SGE-PLC50 Circutor, published on 2 Dec 2025. It can only be exploited from the same machine or local network, with no action from the victim.

Official description

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.

Weakness: CWE-121

Which versions are affected by CVE-2025-11784?

It affects 2 products.

Products include Circutor Sge-Plc1000 Firmware, Circutor Sge-Plc50 Firmware.

How do I fix CVE-2025-11784?

No fix has been published for CVE-2025-11784 yet. Limit exposure of the affected software until one is available.

Upgrade to the fixed version. Memory-safe languages, compiler hardening and fuzzing prevent most new cases. More about Memory corruption.

Is CVE-2025-11784 being exploited?

There is no known exploitation of CVE-2025-11784 in the wild and no public exploit code.

Sources

Also known as GHSA-27h2-hgmw-qj53.

Is CVE-2025-11784 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free