CVE-2025-11788 Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50

High 8.5 Published Updated

Heap-based buffer overflow in Circutor PLCs allows attackers to execute arbitrary code or cause denial of service via oversized meter parameters.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2025-11788?

CVE-2025-11788 is a high-severity memory corruption vulnerability in SGE-PLC1000 SGE-PLC50 Circutor, published on 2 Dec 2025. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

Heap-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowSupervisorParameters()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter.

Weakness: CWE-122

Which versions are affected by CVE-2025-11788?

It affects 2 products.

Products include Circutor Sge-Plc1000 Firmware, Circutor Sge-Plc50 Firmware.

How do I fix CVE-2025-11788?

No fix has been published for CVE-2025-11788 yet. Limit exposure of the affected software until one is available.

Upgrade to the fixed version. Memory-safe languages, compiler hardening and fuzzing prevent most new cases. More about Memory corruption.

Is CVE-2025-11788 being exploited?

There is no known exploitation of CVE-2025-11788 in the wild and no public exploit code.

Sources

Also known as GHSA-p9g3-rphv-8hgj.

Is CVE-2025-11788 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free