{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-1204 exists.","fix":"No fix has been published for CVE-2025-1204 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-1204 is a high-severity vulnerability in Contec Health CMS8000 Patient Monitor, published on 25 Feb 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-1204 and fix it if it is affected.\n\nWhat it is: CVE-2025-1204 is a high-severity vulnerability in Contec Health CMS8000 Patient Monitor, published on 25 Feb 2025. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-1204 exists.\n\nAffected product: Contec Health CMS8000 Patient Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-1204/ (Markdown: https://insights.sbomify.com/CVE-2025-1204/index.md)","id":"CVE-2025-1204","markdown":"https://insights.sbomify.com/CVE-2025-1204/index.md","name":"CVE-2025-1204","record":{"aliases":["GHSA-f9x4-234p-wh9g"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_modify","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Patient Monitor","requires_auth":"none","summary":"Attackers can overwrite device files by impersonating a hard-coded IP address during boot, potentially leading to code execution on the patient monitor.","user_interaction":"required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":7.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-912","name":"Hidden Functionality"}],"description":"The \"update\" binary in the firmware of the affected product sends attempts to mount to a hard-coded, routable IP address, bypassing existing device network settings to do so. The function triggers if the 'C' button is pressed at a specific time during the boot process. If an attacker is able to control or impersonate this IP address, they could upload and overwrite files on the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Hardcoded credentials in CMS8000 Patient Monitor","id":"CVE-2025-1204","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Codezips Gym Management System viewdetailroutine.php sql injection","id":"CVE-2025-1206"},"packages":[],"prev":{"headline":"Slider, Gallery, Carousel by MetaSlider \u003c 3.95.0 - Editor+ Stored XSS","id":"CVE-2025-1203"},"products":["CMS8000 Patient Monitor"],"published":"2025-02-25","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-25","vendors":["Contec Health"]},"summary":"Attackers can overwrite device files by impersonating a hard-coded IP address during boot, potentially leading to code execution on the patient monitor.","url":"https://insights.sbomify.com/CVE-2025-1204/"}