{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-12994 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-12994 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-12994 is a medium-severity vulnerability in Medtronic CareLink Network, published on 4 Dec 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-12994 and fix it if it is affected.\n\nWhat it is: CVE-2025-12994 is a medium-severity vulnerability in Medtronic CareLink Network, published on 4 Dec 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-12994 in the wild and no public exploit code.\n\nAffected product: Medtronic CareLink Network. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-12994/ (Markdown: https://insights.sbomify.com/CVE-2025-12994/index.md)","id":"CVE-2025-12994","markdown":"https://insights.sbomify.com/CVE-2025-12994/index.md","name":"CVE-2025-12994","record":{"aliases":["GHSA-8w88-46cp-7c4j"],"analysis":{"component_type":"web_application","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Medtronic CareLink Network","requires_auth":"none","summary":"Unauthenticated attackers can enumerate valid user accounts via security question API responses in Medtronic CareLink Network.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Medtronic","cpe":[{"product":"carelink_network","vendor":"medtronic"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-204","name":"Observable Response Discrepancy"}],"description":"Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to determine a valid user account. This issue affects CareLink Network: before December 4, 2025.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in CareLink Network","id":"CVE-2025-12994","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in CareLink Network","id":"CVE-2025-12995"},"packages":[],"prev":{"headline":"Denial of Service Vulnerability in Silicon Labs WF200 and WGM160P Devices","id":"CVE-2025-12986"},"products":["CareLink Network"],"published":"2025-12-04","related":[{"cvss_score":8.1,"headline":"Auth bypass in CareLink Network","id":"CVE-2025-12995","kev_date_added":null,"published":"2025-12-04"},{"cvss_score":4.1,"headline":"Information disclosure in CareLink Network","id":"CVE-2025-12996","kev_date_added":null,"published":"2025-12-04"},{"cvss_score":2.2,"headline":"Information disclosure in CareLink Network","id":"CVE-2025-12997","kev_date_added":null,"published":"2025-12-04"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-12-08","vendors":["Medtronic"]},"summary":"Unauthenticated attackers can enumerate valid user accounts via security question API responses in Medtronic CareLink Network.","url":"https://insights.sbomify.com/CVE-2025-12994/"}