{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-13905 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-13905 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-13905 is a high-severity vulnerability in Schneider Electric EcoStruxure™ Process Expert, published on 29 Jan 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-13905 and fix it if it is affected.\n\nWhat it is: CVE-2025-13905 is a high-severity vulnerability in Schneider Electric EcoStruxure™ Process Expert, published on 29 Jan 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-13905 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure™ Process Expert. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-13905/ (Markdown: https://insights.sbomify.com/CVE-2025-13905/index.md)","id":"CVE-2025-13905","markdown":"https://insights.sbomify.com/CVE-2025-13905/index.md","name":"CVE-2025-13905","record":{"aliases":["GHSA-pfjm-7gj6-rrrx"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"EcoStruxure Process Expert","requires_auth":"low_privilege","summary":"Local attackers can escalate privileges by modifying service binaries in the installation folder, leading to code execution upon service restart.","user_interaction":"required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-276","name":"Incorrect Default Permissions"}],"description":"CWE-276: Incorrect Default Permissions vulnerability exists that could cause  privilege escalation through the reverse shell when  one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in EcoStruxure™ Process Expert","id":"CVE-2025-13905","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"WP Flot \u003c= 0.2.2 - Authenticated (Contributor+) Stored Cross-Site Scripting via Shortcode Attributes","id":"CVE-2025-13906"},"packages":[],"prev":{"headline":"WPGancio \u003c= 1.12 - Authenticated (Contributor+) Stored Cross-Site Scripting via Shortcode Attributes","id":"CVE-2025-13904"},"products":["EcoStruxure™ Process Expert","EcoStruxure™ Process Expert for AVEVA System Platform"],"published":"2026-01-29","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-01-29","vendors":["Schneider Electric"]},"summary":"Local attackers can escalate privileges by modifying service binaries in the installation folder, leading to code execution upon service restart.","url":"https://insights.sbomify.com/CVE-2025-13905/"}