{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-14097 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-14097 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-14097 is a high-severity authentication bypass vulnerability in Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX Analyzers, published on 17 Dec 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-14097 and fix it if it is affected.\n\nWhat it is: CVE-2025-14097 is a high-severity authentication bypass vulnerability in Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX Analyzers, published on 17 Dec 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-14097 in the wild and no public exploit code.\n\nAffected product: Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX Analyzers. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-14097/ (Markdown: https://insights.sbomify.com/CVE-2025-14097/index.md)","id":"CVE-2025-14097","markdown":"https://insights.sbomify.com/CVE-2025-14097/index.md","name":"CVE-2025-14097","record":{"aliases":["GHSA-rjfq-mp68-v4f7"],"analysis":{"component_type":"iot_embedded","fix_type":"configuration_change","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":true,"product_category":"Radiometer medical analyzers","requires_auth":"high_privilege","summary":"Attackers can achieve remote code execution and unauthorized device management on Radiometer analyzers if the remote support feature is enabled.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Radiometer","cpe":[],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means.  The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 \u0026 CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\nRequired Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution:\nCustomers should ensure the following:\n•  The network is secure, and access follows best practices.\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                     \nExploit Status:\n\nResearchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Remote Code Execution Vulnerability in Radiometer Products","id":"CVE-2025-14097","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Avira antivirus engine heap buffer OOB write when scanning a malformed MS-DOS executable file","id":"CVE-2025-14098"},"packages":[],"prev":{"headline":"Credential Disclosure vulnerability in Radiometer Products","id":"CVE-2025-14096"},"products":["ABL800 BASIC and ABL800 FLEX Analyzers","ABL90 FLEX and ABL90 FLEX PLUS Analyzers","AQT90 FLEX Analyzers"],"published":"2025-12-17","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-12-17","vendors":["Radiometer Medical Aps"]},"summary":"Attackers can achieve remote code execution and unauthorized device management on Radiometer analyzers if the remote support feature is enabled.","url":"https://insights.sbomify.com/CVE-2025-14097/"}