{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-14749 exists.","fix":"No fix has been published for CVE-2025-14749 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-14749 is a medium-severity missing authorization vulnerability in Ningyuanda TC155, published on 16 Dec 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-14749 and fix it if it is affected.\n\nWhat it is: CVE-2025-14749 is a medium-severity missing authorization vulnerability in Ningyuanda TC155, published on 16 Dec 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-14749 exists.\n\nAffected product: Ningyuanda TC155. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-14749/ (Markdown: https://insights.sbomify.com/CVE-2025-14749/index.md)","id":"CVE-2025-14749","markdown":"https://insights.sbomify.com/CVE-2025-14749/index.md","name":"CVE-2025-14749","record":{"aliases":["GHSA-fmq6-5fmg-5hw5"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"ONVIF PTZ camera","requires_auth":"none","summary":"An attacker on the local network can bypass access controls on the ONVIF device service interface of Ningyuanda TC155 cameras.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"tc155_firmware","vendor":"shenzhenningyuandatechnology"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"},{"id":"CWE-266","name":"Incorrect Privilege Assignment"}],"description":"A vulnerability was identified in Ningyuanda TC155 57.0.2.0. This impacts an unknown function of the file /onvif/device_service of the component ONVIF PTZ Control Interface. The manipulation leads to improper access controls. The attack requires being on the local network. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Ningyuanda TC155 ONVIF PTZ Control device_service access control","id":"CVE-2025-14749","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2025"},"n_packages":0,"n_references":4,"next":{"headline":"External Control of Assumed-Immutable Web Parameter in Weintek cMT X Series HMI EasyWeb Service","id":"CVE-2025-14750"},"packages":[],"prev":{"headline":"Ningyuanda TC155 ONVIF Device Management Service device_service access control","id":"CVE-2025-14748"},"products":["TC155"],"published":"2025-12-16","related":[{"cvss_score":5.3,"headline":"Ningyuanda TC155 RTSP Live Video Stream Endpoint improper authentication","id":"CVE-2025-14746","kev_date_added":null,"published":"2025-12-16"},{"cvss_score":5.3,"headline":"Ningyuanda TC155 RTSP Service denial of service","id":"CVE-2025-14747","kev_date_added":null,"published":"2025-12-16"},{"cvss_score":5.3,"headline":"Ningyuanda TC155 ONVIF Device Management Service device_service access control","id":"CVE-2025-14748","kev_date_added":null,"published":"2025-12-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-12-16","vendors":["Ningyuanda"]},"summary":"An attacker on the local network can bypass access controls on the ONVIF device service interface of Ningyuanda TC155 cameras.","url":"https://insights.sbomify.com/CVE-2025-14749/"}