{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-14771 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-14771 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-14771 is a high-severity vulnerability in ABB T-MAC Plus, published on 3 Jun 2026. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-14771 and fix it if it is affected.\n\nWhat it is: CVE-2025-14771 is a high-severity vulnerability in ABB T-MAC Plus, published on 3 Jun 2026. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-14771 in the wild and no public exploit code.\n\nAffected product: ABB T-MAC Plus. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-14771/ (Markdown: https://insights.sbomify.com/CVE-2025-14771/index.md)","id":"CVE-2025-14771","markdown":"https://insights.sbomify.com/CVE-2025-14771/index.md","name":"CVE-2025-14771","record":{"aliases":["GHSA-287w-267v-h5rm"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"ABB T-MAC Plus","requires_auth":"low_privilege","summary":"External attackers can access sensitive files or directories in the ABB T-MAC Plus web application and server.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ABB","cpe":[{"product":"t-mac_plus","vendor":"abb"}],"cvss":{"score":7.3,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:L/VA:H/SC:H/SI:L/SA:H","version":"4.0"},"cwes":[{"id":"CWE-552","name":"Files or Directories Accessible to External Parties"}],"description":"Files or directories accessible to external parties vulnerability in ABB T-MAC Plus.\n\nThis issue affects T-MAC Plus: 4.0-24.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"File Disclosure in ABB T-MAC Plus web application and in ABB T-MAC plus Server - Default IIS Web Site","id":"CVE-2025-14771","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Broken Access Control in ABB T-MAC Plus web application","id":"CVE-2025-14772"},"packages":[],"prev":{"headline":"Shipping Rate By Cities \u003c= 2.0.0 - Unauthenticated SQL Injection via 'city' Parameter","id":"CVE-2025-14770"},"products":["T-MAC Plus"],"published":"2026-06-03","related":[{"cvss_score":7.3,"headline":"Broken Access Control in ABB T-MAC Plus web application","id":"CVE-2025-14772","kev_date_added":null,"published":"2026-06-03"},{"cvss_score":7.2,"headline":"Stored Cross-Site Scripting in ABB T-MAC Plus web application","id":"CVE-2025-14773","kev_date_added":null,"published":"2026-06-03"},{"cvss_score":7.2,"headline":"Communication analysis between the Card Reader and TP2CardReaderService daemon","id":"CVE-2025-14774","kev_date_added":null,"published":"2026-06-03"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-06-03","vendors":["ABB"]},"summary":"External attackers can access sensitive files or directories in the ABB T-MAC Plus web application and server.","url":"https://insights.sbomify.com/CVE-2025-14771/"}