{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-15080 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-15080 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-15080 is a high-severity vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series R08PCPU, published on 5 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-15080 and fix it if it is affected.\n\nWhat it is: CVE-2025-15080 is a high-severity vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series R08PCPU, published on 5 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-15080 in the wild and no public exploit code.\n\nAffected product: Mitsubishi Electric Corporation MELSEC iQ-R Series R08PCPU. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-15080/ (Markdown: https://insights.sbomify.com/CVE-2025-15080/index.md)","id":"CVE-2025-15080","markdown":"https://insights.sbomify.com/CVE-2025-15080/index.md","name":"CVE-2025-15080","record":{"aliases":["GHSA-3pq4-wgqv-gq3h"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","data_modify","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Mitsubishi PLC","requires_auth":"none","summary":"Unauthenticated attackers can read or modify device data and cause denial of service on Mitsubishi MELSEC iQ-R PLCs via crafted packets.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Mitsubishi","cpe":[],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-1284","name":"Improper Validation of Specified Quantity in Input"}],"description":"Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric MELSEC iQ-R Series R08PCPU, R16PCPU, R32PCPU, and R120PCPU allows an unauthenticated attacker to read device data or part of a control program from the affected product, write device data in the affected product, or cause a denial of service (DoS) condition on the affected product by sending a specially crafted packet containing a specific command to the affected product.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in MELSEC iQ-R Series R08PCPU","id":"CVE-2025-15080","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2025"},"n_packages":0,"n_references":3,"next":{"headline":"JD Cloud BE6500 jdcapi sub_4780 command injection","id":"CVE-2025-15081"},"packages":[],"prev":{"headline":"libssh global known_hosts override","id":"CVE-2025-15079"},"products":["MELSEC iQ-R Series R08PCPU","MELSEC iQ-R Series R120PCPU","MELSEC iQ-R Series R16PCPU","MELSEC iQ-R Series R32PCPU"],"published":"2026-02-05","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-02-06","vendors":["Mitsubishi Electric Corporation"]},"summary":"Unauthenticated attackers can read or modify device data and cause denial of service on Mitsubishi MELSEC iQ-R PLCs via crafted packets.","url":"https://insights.sbomify.com/CVE-2025-15080/"}