{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-15161 exists.","fix":"No fix has been published for CVE-2025-15161 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-15161 is a high-severity memory corruption vulnerability in Tenda WH450, published on 28 Dec 2025. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-15161 and fix it if it is affected.\n\nWhat it is: CVE-2025-15161 is a high-severity memory corruption vulnerability in Tenda WH450, published on 28 Dec 2025. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2025-15161 exists.\n\nAffected product: Tenda WH450. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-15161/ (Markdown: https://insights.sbomify.com/CVE-2025-15161/index.md)","id":"CVE-2025-15161","markdown":"https://insights.sbomify.com/CVE-2025-15161/index.md","name":"CVE-2025-15161","record":{"aliases":["GHSA-whx8-c8r7-rv23"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda WH450 router","requires_auth":"high_privilege","summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda WH450 router via the PPTPUserSetting interface, potentially leading to code execution.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"wh450_firmware","vendor":"tenda"}],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"},{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A vulnerability was found in Tenda WH450 1.0.0.18. Affected is an unknown function of the file /goform/PPTPUserSetting. Performing a manipulation of the argument delno results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda WH450 PPTPUserSetting stack-based overflow","id":"CVE-2025-15161","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"Tenda WH450 RouteStatic stack-based overflow","id":"CVE-2025-15162"},"packages":[],"prev":{"headline":"Tenda WH450 PPTPServer stack-based overflow","id":"CVE-2025-15160"},"products":["WH450"],"published":"2025-12-28","related":[{"cvss_score":9.3,"headline":"Tenda WH450 NatStaticSetting stack-based overflow","id":"CVE-2025-15044","kev_date_added":null,"published":"2025-12-23"},{"cvss_score":9.3,"headline":"Tenda WH450 HTTP Request Natlimit stack-based overflow","id":"CVE-2025-15045","kev_date_added":null,"published":"2025-12-23"},{"cvss_score":9.3,"headline":"Tenda WH450 HTTP Request PPTPClient stack-based overflow","id":"CVE-2025-15046","kev_date_added":null,"published":"2025-12-23"},{"cvss_score":9.3,"headline":"Tenda WH450 HTTP Request PPTPDClient stack-based overflow","id":"CVE-2025-15047","kev_date_added":null,"published":"2025-12-23"},{"cvss_score":9.3,"headline":"Tenda WH450 HTTP Request CheckTools stack-based overflow","id":"CVE-2025-15006","kev_date_added":null,"published":"2025-12-22"},{"cvss_score":9.3,"headline":"Tenda WH450 HTTP Request L7Im stack-based overflow","id":"CVE-2025-15007","kev_date_added":null,"published":"2025-12-22"},{"cvss_score":9.3,"headline":"Tenda WH450 SafeUrlFilter stack-based overflow","id":"CVE-2025-15010","kev_date_added":null,"published":"2025-12-22"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-02-24","vendors":["Tenda"]},"summary":"Remote attackers can trigger a stack-based buffer overflow in the Tenda WH450 router via the PPTPUserSetting interface, potentially leading to code execution.","url":"https://insights.sbomify.com/CVE-2025-15161/"}