{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-1679 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-1679 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-1679 is a medium-severity cross-site scripting vulnerability in Moxa TN-4500A Series, published on 23 Oct 2025. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-1679 and fix it if it is affected.\n\nWhat it is: CVE-2025-1679 is a medium-severity cross-site scripting vulnerability in Moxa TN-4500A Series, published on 23 Oct 2025. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-1679 in the wild and no public exploit code.\n\nAffected product: Moxa TN-4500A Series. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-1679/ (Markdown: https://insights.sbomify.com/CVE-2025-1679/index.md)","id":"CVE-2025-1679","markdown":"https://insights.sbomify.com/CVE-2025-1679/index.md","name":"CVE-2025-1679","record":{"aliases":["GHSA-pfrw-8vrh-4v8w"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Moxa Ethernet switch","requires_auth":"high_privilege","summary":"Authenticated attackers can inject persistent scripts into Moxa switch web interfaces, impacting other authenticated users.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Moxa","cpe":[],"cvss":{"score":4.8,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N","version":"4.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"Cross-site Scripting has been identified in Moxa’s Ethernet switches, which allows an authenticated administrative attacker to inject malicious scripts to an affected device’s web service that could impact authenticated users interacting with the device’s web interface. This vulnerability is classified as stored cross-site scripting (XSS); attackers inject malicious scripts into the system, and the scripts persist across sessions. There is no impact to the confidentiality, integrity, and availability of the affected device; no loss of availability within any subsequent systems but has some loss of confidentiality and integrity within the subsequent system.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in TN-4500A Series","id":"CVE-2025-1679","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2025"},"n_packages":0,"n_references":2,"next":{"headline":"Open redirect in TN-4500A Series","id":"CVE-2025-1680"},"packages":[],"prev":{"headline":"Allocation of Resources Without Limits or Throttling in GitLab","id":"CVE-2025-1677"},"products":["TN-4500A Series","TN-5500A Series","TN-G4500 Series","TN-G6500 Series"],"published":"2025-10-23","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-10-23","vendors":["Moxa"]},"summary":"Authenticated attackers can inject persistent scripts into Moxa switch web interfaces, impacting other authenticated users.","url":"https://insights.sbomify.com/CVE-2025-1679/"}