{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-23008 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-23008 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-23008 is a high-severity vulnerability in SonicWall NetExtender, published on 10 Apr 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-23008 and fix it if it is affected.\n\nWhat it is: CVE-2025-23008 is a high-severity vulnerability in SonicWall NetExtender, published on 10 Apr 2025. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-23008 in the wild and no public exploit code.\n\nAffected product: SonicWall NetExtender. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-23008/ (Markdown: https://insights.sbomify.com/CVE-2025-23008/index.md)","id":"CVE-2025-23008","markdown":"https://insights.sbomify.com/CVE-2025-23008/index.md","name":"CVE-2025-23008","record":{"aliases":["GHSA-9f82-pr9c-9f3x"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["privilege_escalation","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"SonicWall NetExtender client","requires_auth":"low_privilege","summary":"A low-privileged attacker can modify configurations in the SonicWall NetExtender Windows client due to improper privilege management.","user_interaction":"required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"sonicwall","cpe":[],"cvss":{"score":7.2,"severity":"high","source":"cisa-adp","vector":"CVSS:3.1/AV:P/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-250","name":"Execution with Unnecessary Privileges"}],"description":"An improper privilege management vulnerability in the SonicWall NetExtender Windows (32 and 64 bit) client allows a low privileged attacker to modify configurations.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in NetExtender","id":"CVE-2025-23008","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Privilege escalation in NetExtender","id":"CVE-2025-23009"},"packages":[],"prev":{"headline":"Privilege escalation in NetExtender","id":"CVE-2025-23007"},"products":["NetExtender"],"published":"2025-04-10","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-10","vendors":["SonicWall"]},"summary":"A low-privileged attacker can modify configurations in the SonicWall NetExtender Windows client due to improper privilege management.","url":"https://insights.sbomify.com/CVE-2025-23008/"}