{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-23169 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-23169 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-23169 is a medium-severity cross-site scripting vulnerability in Versa Director, published on 18 Jun 2025. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2025-23169 and fix it if it is affected.\n\nWhat it is: CVE-2025-23169 is a medium-severity cross-site scripting vulnerability in Versa Director, published on 18 Jun 2025. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2025-23169 in the wild and no public exploit code.\n\nAffected product: Versa Director. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-23169/ (Markdown: https://insights.sbomify.com/CVE-2025-23169/index.md)","id":"CVE-2025-23169","markdown":"https://insights.sbomify.com/CVE-2025-23169/index.md","name":"CVE-2025-23169","record":{"aliases":["GHSA-grg9-576x-5279"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["code_execution","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"SD-WAN orchestration platform","requires_auth":"high_privilege","summary":"Attackers can inject stored XSS payloads via unvalidated UI customization inputs in Versa Director, potentially leading to session hijacking or malicious script execution.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"hackerone","cpe":[{"product":"versa_director","vendor":"versa-networks"}],"cvss":{"score":6.1,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"The Versa Director SD-WAN orchestration platform allows customization of the user interface, including the header, footer, and logo. However, the input provided for these customizations is not properly validated or sanitized, allowing a malicious user to inject and store cross-site scripting (XSS) payloads. \r\n\r\nExploitation Status: \r\n\r\nVersa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers.  \r\n\r\nWorkarounds or Mitigation: \r\n\r\nThere are no workarounds to disable the GUI option. Versa recommends that Director be upgraded to one of the remediated software versions.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in Director","id":"CVE-2025-23169","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2025"},"n_packages":0,"n_references":5,"next":{"headline":"Command injection in Director","id":"CVE-2025-23170"},"packages":[],"prev":{"headline":"Security feature bypass in Director","id":"CVE-2025-23168"},"products":["Director"],"published":"2025-06-18","related":[{"cvss_score":6.6,"headline":"Versa Director Dangerous File Type Upload","id":"CVE-2024-39717","kev_date_added":"2024-08-23","published":"2024-08-22"},{"cvss_score":10,"headline":"Hardcoded credentials in Director","id":"CVE-2024-42450","kev_date_added":null,"published":"2024-11-19"},{"cvss_score":9.8,"headline":"Hardcoded credentials in Director","id":"CVE-2025-24288","kev_date_added":null,"published":"2025-06-18"},{"cvss_score":9.8,"headline":"Command injection in Versa Director","id":"CVE-2019-25029","kev_date_added":null,"published":"2021-05-26"},{"cvss_score":7.5,"headline":"Information disclosure in Director","id":"CVE-2025-23173","kev_date_added":null,"published":"2025-06-18"},{"cvss_score":7.2,"headline":"File upload in Director","id":"CVE-2025-23171","kev_date_added":null,"published":"2025-06-18"},{"cvss_score":7.2,"headline":"Server-side request forgery in Director","id":"CVE-2025-23172","kev_date_added":null,"published":"2025-06-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-06-23","vendors":["Versa"]},"summary":"Attackers can inject stored XSS payloads via unvalidated UI customization inputs in Versa Director, potentially leading to session hijacking or malicious script execution.","url":"https://insights.sbomify.com/CVE-2025-23169/"}