{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2025-23376 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-23376 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-23376 is a low-severity code injection vulnerability in Dell PowerProtect Data Manager Reporting, published on 28 Apr 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-23376 and fix it if it is affected.\n\nWhat it is: CVE-2025-23376 is a low-severity code injection vulnerability in Dell PowerProtect Data Manager Reporting, published on 28 Apr 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-23376 in the wild and no public exploit code.\n\nAffected product: Dell PowerProtect Data Manager Reporting. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-23376/ (Markdown: https://insights.sbomify.com/CVE-2025-23376/index.md)","id":"CVE-2025-23376","markdown":"https://insights.sbomify.com/CVE-2025-23376/index.md","name":"CVE-2025-23376","record":{"aliases":["GHSA-x238-v9f9-93g8"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Dell PowerProtect Data Manager","requires_auth":"high_privilege","summary":"A high-privileged local attacker can exploit a template engine vulnerability in Dell PowerProtect Data Manager Reporting to disclose sensitive information.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"powerprotect_data_manager","vendor":"dell"}],"cvss":{"score":2.3,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-94","name":"Improper Control of Generation of Code"},{"id":"CWE-1336","name":"Improper Neutralization of Special Elements Used in a Template Engine"}],"description":"Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Code injection in PowerProtect Data Manager Reporting","id":"CVE-2025-23376","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site scripting in PowerProtect Data Manager","id":"CVE-2025-23377"},"packages":[],"prev":{"headline":"Privilege escalation in PowerProtect Data Manager","id":"CVE-2025-23375"},"products":["PowerProtect Data Manager Reporting"],"published":"2025-04-28","related":[{"cvss_score":9.1,"headline":"Privilege escalation in PowerProtect Data Manager","id":"CVE-2026-40712","kev_date_added":null,"published":"2026-07-22"},{"cvss_score":9.1,"headline":"Privilege escalation in PowerProtect Data Manager","id":"CVE-2026-46738","kev_date_added":null,"published":"2026-07-22"},{"cvss_score":8.8,"headline":"Privilege escalation in PowerProtect Data Manager","id":"CVE-2026-49499","kev_date_added":null,"published":"2026-07-22"},{"cvss_score":8.8,"headline":"Information disclosure in PowerProtect Data Manager","id":"CVE-2025-43888","kev_date_added":null,"published":"2025-09-10"},{"cvss_score":8.8,"headline":"Auth bypass in PowerProtect Data Manager","id":"CVE-2024-22454","kev_date_added":null,"published":"2024-02-13"},{"cvss_score":8.8,"headline":"Missing authorization in PPDM Reporting (PowerProtect Data Manager)","id":"CVE-2023-28062","kev_date_added":null,"published":"2023-04-11"},{"cvss_score":8.2,"headline":"Command injection in PowerProtect Data Manager","id":"CVE-2025-43884","kev_date_added":null,"published":"2025-09-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-28","vendors":["Dell"]},"summary":"A high-privileged local attacker can exploit a template engine vulnerability in Dell PowerProtect Data Manager Reporting to disclose sensitive information.","url":"https://insights.sbomify.com/CVE-2025-23376/"}