{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-24285 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-24285 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-24285 is a critical command injection vulnerability in Ubiquiti Inc UniFi Connect EV Station Lite, published on 21 Aug 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-24285 and fix it if it is affected.\n\nWhat it is: CVE-2025-24285 is a critical command injection vulnerability in Ubiquiti Inc UniFi Connect EV Station Lite, published on 21 Aug 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-24285 in the wild and no public exploit code.\n\nAffected product: Ubiquiti Inc UniFi Connect EV Station Lite. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-24285/ (Markdown: https://insights.sbomify.com/CVE-2025-24285/index.md)","id":"CVE-2025-24285","markdown":"https://insights.sbomify.com/CVE-2025-24285/index.md","name":"CVE-2025-24285","record":{"aliases":["GHSA-5fjw-g444-whhx"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"EV charging station","requires_auth":"none","summary":"A malicious actor with network access can execute arbitrary commands on the UniFi Connect EV Station Lite due to improper input validation.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"hackerone","cpe":[],"cvss":{"score":9.8,"severity":"critical","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"Multiple Improper Input Validation vulnerabilities in UniFi Connect EV Station Lite may allow a Command Injection by a malicious actor with network access to the UniFi Connect EV Station Lite.\r\n \r\nAffected Products:\r\nUniFi Connect EV Station Lite (Version 1.5.1 and earlier)\r\n \r\nMitigation:\r\nUpdate UniFi Connect EV Station Lite to Version 1.5.2 or later","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in UniFi Connect EV Station Lite","id":"CVE-2025-24285","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Privilege escalation in Backup and Recovery","id":"CVE-2025-24286"},"packages":[],"prev":{"headline":"Security feature bypass in macOS","id":"CVE-2025-24284"},"products":["UniFi Connect EV Station Lite"],"published":"2025-08-21","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-02-26","vendors":["Ubiquiti Inc"]},"summary":"A malicious actor with network access can execute arbitrary commands on the UniFi Connect EV Station Lite due to improper input validation.","url":"https://insights.sbomify.com/CVE-2025-24285/"}