{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2025-24292 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2025-24292 yet. Limit exposure of the affected software until one is available.","what":"CVE-2025-24292 is a medium-severity authentication bypass vulnerability in Ubiquiti Inc UniFi Network Application, published on 29 Jun 2025. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2025-24292 and fix it if it is affected.\n\nWhat it is: CVE-2025-24292 is a medium-severity authentication bypass vulnerability in Ubiquiti Inc UniFi Network Application, published on 29 Jun 2025. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2025-24292 in the wild and no public exploit code.\n\nAffected product: Ubiquiti Inc UniFi Network Application. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2025-24292/ (Markdown: https://insights.sbomify.com/CVE-2025-24292/index.md)","id":"CVE-2025-24292","markdown":"https://insights.sbomify.com/CVE-2025-24292/index.md","name":"CVE-2025-24292","record":{"aliases":["GHSA-3cm8-v4wq-9mhf"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":true,"product_category":"UniFi Network Application","requires_auth":"none","summary":"Attackers can bypass authentication for Enterprise WiFi or VPN by exploiting a misconfigured RADIUS profile shared between services.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"hackerone","cpe":[],"cvss":{"score":6.8,"severity":"medium","source":"cna","vector":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"A misconfigured query in UniFi Network (v9.1.120 and earlier) could allow users to authenticate to Enterprise WiFi or VPN Server (l2tp and OpenVPN) using a device’s  MAC address from 802.1X or MAC Authentication, if both services are enabled and share the same RADIUS profile.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in UniFi Network Application","id":"CVE-2025-24292","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2025"},"n_packages":0,"n_references":1,"next":{"headline":"Active Storage allowed transformation methods that were potentially unsafe","id":"CVE-2025-24293"},"packages":[],"prev":{"headline":"File upload in Director","id":"CVE-2025-24291"},"products":["UniFi Network Application"],"published":"2025-06-29","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-06-30","vendors":["Ubiquiti Inc"]},"summary":"Attackers can bypass authentication for Enterprise WiFi or VPN by exploiting a misconfigured RADIUS profile shared between services.","url":"https://insights.sbomify.com/CVE-2025-24292/"}